MAINTENANCE

4)

  Make a  periodic check of burner for proper 

position and condition. Visually check the 

fl ame of the burner periodically, making sure 

the fl ames are steady; not lifting or fl oating. 

If there is a problem, call a qualifi ed service 

person. 

5)

  The appliance and venting system must be 

inspected before use, and at least annually, 

by a qualifi ed fi eld service person, to ensure 

that the fl ow of combustion and ventilation 

air is not obstructed.

Note:  Never operate the appliance without 

the  glass  properly  secured  in 

place.

6)

  Do not use this appliance if any part has been 

under  water.  Immediately  call  a  qualifi ed 

service technician to inspect the appliance 

and to replace any part of the control system 

and any gas control which has been under 

water.

7)

  Verify operation after servicing.

General Vent Maintenance

Conduct an inspection of the venting system 

semi-annually. Recommended areas to inspect 

as follows:

1)

  Check the Venting System for corrosion in 

areas  that  are  exposed  to  the  elements. 

These  will  appear  as  rust  spots  or 

streaks,  and  in  extreme  cases,  holes. 

These  components  should  be  replaced 

immediately.

2)

  Remove  the  Cap,  and  shine  a  fl ashlight 

down the Vent. Remove any bird nests, or 

other foreign material.

3)

  Check  for  evidences  of  excessive 

condensation, such as water droplets forming 

in the inner liner, and subsequently dripping 

out the joints, Continuous condensation can 

cause corrosion of caps, pipe, and fi ttings. 

It  may  be  caused  by  having  excessive 

lateral runs, too many elbows, and exterior 

portions  of  the  system  being  exposed  to 

cold weather.

4)

  Inspect  joints,  to  verify  that  no  pipe 

sections  or  fi ttings  have  been  disturbed, 

and  consequently  loosened.  Also  check 

mechanical supports such as Wall Straps, 

or plumbers' tape for rigidity.

GOLD-PLATED 

OR BRASS TRIM

The 24 carat gold plated or brass fi nish on the 

trim requires little maintenance, and need only 

be  cleaned  with  a  damp  cloth.  DO  NOT  use 

abrasive materials or chemical cleaners, as they 

may harm the fi nish and void the warranty.

Clean any fi ngerprints off before turning the 

unit on. If the top louvers start to discolour, 

check  the  door  gasket  seal  and  replace  if 

necessary.

LOG REPLACEMENT

The unit should never be used with broken logs. 

Turn off the gas valve and allow the unit to cool 

before opening door and carefully remove the 

logs. (The pilot light generates enough heat to 

burn someone.) If for any reason a log should 

need  replacement,  you  must  use  the  proper 

replacement  log.  The  position  of  these  logs 

must be as shown in the diagrams under Log 

Installation.

Note:  Improper positioning of logs may create 

carbon build-up and will severely alter 

the unit's performance which is not 

covered under warranty.

THERMOPILE / 

THERMOCOUPLE

1)

  Open the bottom louvers.

2)

  Loosen the thermocouple or thermopile with 

a 7/16" wrench.

3)

  Disconnect  thermocouple  by  loosening 

nut  from  the  valve  with  a  9mm  wrench. 

Disconnect thermopile by loosening 2 screws 

marked TP on the valve.

4)

  Drop the thermocouple or thermopile down 

from the bracket and pull it out of the unit.

5)

  Reinstall the new ones in reverse order.

GLASS GASKET

If the glass gasket requires replacement use  

a tadpole glass gasket for the Flush Front (Part 

# 936-155).   

DOOR GLASS

Your UltraGlow

®

 fi replace is supplied with high 

temperature,  5  mm  tempered  glass  that  will 

withstand the highest heat that your unit will 

produce.   If your glass requires cleaning, we 

recommend using an approved glass cleaner 

available at all authorized dealers. Do not use 

abrasive  materials.  Do  not  clean  the  glass 

when hot.

In the event that you break your glass by impact, 

purchase your replacement from an authorized 

UltraGlow

®

 dealer only, and follow our step-by-

®

®

step instructions for replacement.

WARNING: Do not operate the appliance 

with the glass panels removed, cracked 

or  broken.  Replacement  of  the  glass  

panels should be done by a licensed 

or qualifi ed service person.

Caution: Wear gloves when removing 

damaged or broken glass.

Flush Glass Replacement

Remove the fl ush door front (as per instructions 

in the "Standard Flush Door" section). Remove 

the 4 glass clips from each corner. Slide in the 

new replacement glass. Push the 4 glass clips 

back onto the frame.  

The glass must have 

gasketing around it.

Содержание G36D

Страница 1: ...ly for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certi ed kit is used FOR YOUR SAFETY What to do if you smell gas Do no...

Страница 2: ...AT HIGH ATLITUDES CAN CGA 2 17 M91 This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and Safety...

Страница 3: ...ments 6 Locating Your Gas Stove 6 Clearances 7 Mantel Leg Clearances 7 Framing And Finishing 7 Combustible Mantels 8 Unit Assembly Prior To Installation 9 Venting Introduction 9 Exterior Vent Terminat...

Страница 4: ...Btu h 3 96 kW 0 4500 ft pi 0 1372 m 26 000 B 7 91 tu h kW APPAREIL FONCTIONNANT AU NATURAL GAZ CONCU POUR ETRE POELE Pression d allimentation minimum Pression la tubulure d chappement lev e Pression l...

Страница 5: ...rvent to another room or inside a building Make sure that the vent is tted as per Venting instructions 5 Inspect the venting system annually for blockage and any signs of deterioration 6 Venting termi...

Страница 6: ...other than wood ooring the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 4 The G36D Direct Vent Gas Fireplace can be installedinarecessedpos...

Страница 7: ...Horizontal Vent Clearances Top 2 1 2 64mm Side 1 1 2 38mm Bottom 1 1 2 38mm Vertical Vent Clearances 1 1 4 32mm Alcove Clearances Max Depth 36 914mm Min Width 48 1219mm Min Height 72 1829mm see mantl...

Страница 8: ...learances from top of unit are shown in the diagram below Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Th...

Страница 9: ...side nailing strip using 3 screws VENTING INTRODUCTION The G36D uses the balanced ue technology Co Axial system The inner liner vents products of combustion to the outside while the outer liner draws...

Страница 10: ...r with AstroCap Termination Cap min 6 15cm with Dura Vent Termination Cap 12 30cm H Not to be installed above a meter regulator assembly within 3 90cm horizontally from the centerline of the regulator...

Страница 11: ...cations section UltraGlow UltraGlow UltraGlow Direct Vent Flex Termination Kit Part 946 515 includes all the parts Direct Vent Flex Termination Kit Part 946 515 includes all the parts needed to instal...

Страница 12: ...45O Elbow Galvinized 945 4DT EL45 4D45L 45O Elbow Black 945B 4DT EL45B 4D45LB 45O Elbow Swivel Galvinized 945G N A N A 45O Elbow Swivel Black 945BG N A N A 90O Elbow Galvinized 990 4DT EL90S 4D90LS 9...

Страница 13: ...nation Caps When using Rigid Vent piping other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor The FPI AstroCapTM and FPI Riser Vent terminal are certi ed for installation...

Страница 14: ...gid vent systems All Rigid Pipe Systems All Rigid Pipe Systems 4 inner diameter 6 5 8 outer diameter UltraGlow UltraGlow UltraGlow UltraGlow Flex Vent Flex Vent 4 inner diameter 6 7 8 inner diameter M...

Страница 15: ...orizontal termination arrangements by using chart in the Rigid Pepi Venting Arrangements Vertical Termination section and deducting 3 ft 0 9m from the maximum horizontal distance for the second 90o el...

Страница 16: ...aight vertical including a maximum 20 0 5m horizontal offset using two 90o elbow two 45o elbows equal one 90o elbow with Rigid Pipe vent systems for Propane and Natural Gas as per diagram 2 Vent must...

Страница 17: ...The shaded area in the diagram 3 shows all allowable combinations of straight vertical and offset to vertical terminations with Rigid Pipe vent systems for Propane and Natural Gas Maximum two 45o elb...

Страница 18: ...DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit which contains the following Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adaptor...

Страница 19: ...nt Gas Fireplace 19 INSTALLATION VENTING ARRANGEMENTS VERTICAL TERMINATIONS with Co linear Flex System for both Residential Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams s...

Страница 20: ...esigned to slide straight onto the male ends of adjacent pipes and ttings by orienting the four pipe indentations so they match and slide in to the four entry slots on the male ends Diagram1 Pushthepi...

Страница 21: ...at ceiling or wall cut a 10inchsquarehole Frametheholeasshown in Diagram 3 and install the restop 4 Assemble the desired lengths of pipe and elbows Ensure that all pipes and elbow connections are in t...

Страница 22: ...or UltraGlow Direct Vent Direct Vent System Flex 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the...

Страница 23: ...ng around the thermopile 1 around the thermocouple and 1 owing across the burner it does not have to be touching the burner Note Ifyouhaveanincorrect amepattern contact your Regency dealer for further...

Страница 24: ...ntil it is free and extract it 13 Check that the screw is clean and if necessary remove dirt 14 Flip the screw Fig 3 Fig 1 Fig 2 Fig 3 8 Remove burner ori ce with a 1 2 wrench and discard Use another...

Страница 25: ...rted to LPG near or on top of the serial decal Installation of the DC Sparker 15 Using the Allen wrench as shown in Fig 4 rotate the screw clockwise until snug do not overtighten Fig 4 Fig 4 21 Locate...

Страница 26: ...re into place with the velcro which is provided in the kit Heat Shield 29 Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield 34 Tie up the loose w...

Страница 27: ...force into position 3 Place Log 02 75 on the rear log support pins with the at side to the back The 02 refer numbers i e 02 75 are molded into the rear of each log 02 52 02 54 Notch a 02 75 Rear Log b...

Страница 28: ...utouts 8 PlaceLog02 52betweenLogs02 51and02 75andontheindentation on Log 02 54 The bottom right end sits behind the rear grate tab Front Brackets Notch 9 Sit Log 02 50 on the front left side of the bu...

Страница 29: ...make sure ame ows smoothly from one end of burner to the other If there is any ame hesitation check that area for any blockage of the burner ports 12 Install ush glass as per instructions in manual Do...

Страница 30: ...to side 2 The bottom louver has a hinge that is attached 2 screws per hinge to the lip on bottom of the unit 3 Open the bottom louver Pull the Burner ON OFF control box from inside the bottom of the r...

Страница 31: ...nient location on the wall to install the receiver and the receptacle box protection from extreme heat is very important Run wires from the replace to that location Use the Thermostat Wire Table 2 Con...

Страница 32: ...e of a power failure the burner switch and the optional remote control thermostat will continue to operate Do not cut the ground terminal off under any circumstances Caution Ensure that the wires do n...

Страница 33: ...ire extra space to slide the fan to the back the left spring can be unhooked from the bracket Note A 120 Volt AC power cord can be installed at rough in stage so that the power is available A three wi...

Страница 34: ...curing process To ensure that the paint is properly cured it is recommended that you burn your replace for at least four 4 hours the rst time before you use it with the fan on When rst operated the u...

Страница 35: ...explosion D Do not use this appliance if any part has been under water Immediately call a quali ed service technician to inspect the appliance and to replace any part of the control system and any gas...

Страница 36: ...nish and void the warranty Clean any ngerprints off before turning the unit on If the top louvers start to discolour check the door gasket seal and replace if necessary LOG REPLACEMENT The unit shoul...

Страница 37: ...embly Note Failure to install a new gasket may severely affect the appliance performance 9 Reinstall the 12 hold down screws 10 Hook up the 2 TP and 2 TH wires to the appropriate connections on the va...

Страница 38: ...04 687 Clamp Connector 20 510 033 Top Nailing Strip 21 510 064 Side Nailing Strip 23 780 011 Standoff Top 24 780 013 Standoff Side Back Part Description 27 Outer Flue Collar 28 Inner Flue Collar Assy...

Страница 39: ...S I T Natural Gas 910 380 Valve S I T Propane 58 Valve Bracket 65 Pilot Bracket 66 910 038 Pilot Assy S I T 3 Flame NG 910 039 Pilot Assy S I T 3 Flame LP 67 Pilot Holder 68 W840470 Pilot Assembly Ga...

Страница 40: ...lush Glass Trim Set Brass 510 947 Flush Glass Trim Set Steel 510 932 Flush Glass Trim Set Gold 132 904 196 Magnet 1 Round 133 780 069 Flush Louver Top Black 134 786 520 Assembly Bottom Black 135 940 3...

Страница 41: ...____________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _______________...

Страница 42: ...___________________________________________________ ___________________________________________________ ___________________________________________________ ____________________________________________...

Страница 43: ...s At all times FPI reserves the right to inspect product in the eld which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitte...

Страница 44: ...__________________________________________________ Phone ___________________________________________________________ Date Installed ______________________________________________________ Serial No ___...

Отзывы: