![UltraGauge EM Скачать руководство пользователя страница 46](http://html2.mh-extra.com/html/ultragauge/em/em_installation-and-operation-manual_3465477046.webp)
____________________________________________________________________________________________
Page 46/55 UltraGauge™ EM User Manual www.ultra-gauge.com
BACK Alarm
Coolant Temp (
º
F)
MIN
MAX
Off
on
0
250
(-40)
(419)
A
A
L
L
A
A
R
R
M
M
S
S
.
.
.
.
Alarms can be set for every gauge. Alarms may also be optionally enabled for newly posted trouble codes and pending trouble codes.
Each gauge can have a high and low alarm. Each Low and High Alarm can individually be enabled and the value of each high and low
alarm threshold can be individually set. UltraGauge continually compares real-time gauge values to each of the alarm values. If the
real-time value is greater than the high alarm or less than the low alarm, an alarm is initiated. The Alarm is both audible and visual. The
audible portion of the alarm may be disabled if so desired. Alarms as a whole can also be disabled. During an alarm, the alarm may be
suspended by pressing the DOWN key. Once suspended, the alarm for that specific gauge will no longer trigger. However, the
suspended alarm will be again be enabled when the ignition is switched from RUN to OFF.
S
S
e
e
t
t
G
G
a
a
u
u
g
g
e
e
A
A
l
l
a
a
r
r
m
m
s
s
.
.
.
.
MENU
Alarms ..
Set Gauge Alarms ..
Each Gauge has both a Min and Max Alarm. For example, a temperature gauge has both a high temperature alarm and a low
temperature alarm. Whenever the alarm value is exceeded the alarms sounds. Each alarm can be individually enable or disabled
and the value for that alarm can be set. By default many of the alarms are enabled and factory default values are set.
On the last row of each alarm is a value that represents the extreme limits for that particular gauge.
To set or enable an alarm:
1.
select
MENU
Alarms ..
Set Gauge Alarms ..
2.
Use the
UP
&
DOWN
keys to Navigate to the desired Gauge. Press
Next
or
Back
to advance to the next group of gauges
3.
While the cursor is positioned next to the desired gauge, Press
MENU.
This will show the alarm screen for that gauge, as
shown below.
4.
Pressing
UP
or
DOWN
will cause the cursor to move around the alarm window.
5.
While positioned over the off/on selection for the Alarm, pressing
MENU
will toggle the alarm from on to off and off to on.
6.
While positioned over the Value field, pressing
MENU
will cause the cursor to blink, signifying data entry mode. Use the
UP
and
DOWN
keys to advance the value to the desired value. The Alarm will only trigger when the measured value
exceeds the trigger value. Note that the value will always be just short, by the least significant digit, of the maximum value,
since if the max value was set, the alarm would never trigger. Press
MENU
to finalize the setting
7.
Select
BACK
to exit the alarm menu for the particular gauge
All settings are saved as they are made. The UltraGauge
configuration is stored in non-volatile memory so that it is
preserved through vehicle start/stop cycles or unplugging of the
unit. The configuration remains until the user chooses to change
it.
A
A
l
l
a
a
r
r
m
m
s
s
i
i
r
r
e
e
n
n
o
o
n
n
/
/
o
o
f
f
f
f
MENU
Alarms ..
Alarm siren on/off
Allows the audible alarm siren to be switched on or off. This only affects the audible siren and does not
affect the visible siren. This does not affect key press tones.
A
A
l
l
l
l
a
a
l
l
a
a
r
r
m
m
s
s
o
o
n
n
/
/
o
o
f
f
f
f
MENU
Alarms ..
All Alarms on/off
Globally enables or disables all Gauge Alarms both audible and visual.
A
A
l
l
a
a
r
r
m
m
s
s
i
i
r
r
e
e
n
n
f
f
r
r
e
e
q
q
MENU
Alarms ..
Alarm Siren Freq
Allows the frequency of the alarm siren to be adjusted. By default the frequency of the siren is set to 4450 Hz. This typically
represents the optimal frequency for maximizing volume and clarity. The frequency can be adjusted from 3000-5000Hz. Set the
frequency to a value that is best suited for your hearing.