PREVENTIVE MAINTENANCE
Minimal maintenance is required on a 14" (356 mm) electric fryer because of its design and materials used in the manufacturing
process. However some preventive maintenance and inspection must be performed periodically to prevent breakdowns which
could curtail food sales. Any preventive maintenance or inspection should be accomplished with
CAUTION
while the fryer is
in operation since
HOT
liquid shortening could cause severe burns. If service or repair is required, all electrical power
MUST
BE TURNED OFF PRIOR TO
performing that service or repair.
PREVENTIVE MAINTENANCE SCHEDULE
DAILY
ITEM
INSPECT
FOR
Grease Filters
Clean grease filters in the exhaust vet hood every evening and
allow
them
to
dry
overnight
WEEKLY
ITEM
INSPECT
FOR
Drain Valve Handle
Determine the Drain Valve Handle is securely attached to the
drain valve and that the valve and be easily opened and closed
Temperature Sensing Probes
During boil-out of the fryer, inspect the temperature and hi-limit
sensing
probes
for
any
visual
damage
18
PN 30A255 June 2014 Rev A
CAUTION:
TURN OFF FRYER POWER BEFORE LIFTING HEATING ELEMENTS OUT OF WATER
OR SHORTENING
Содержание F-E21-14
Страница 4: ...GENERAL INFORMATION PN 30A255 June 2014 Rev A 4...
Страница 5: ...PN 30A255 June 2014 Rev A 5...
Страница 10: ...PRE INSTALLATION PN 30A255 June 2014 Rev A 10...
Страница 12: ...RECEIVING AND INSTALLING PN 30A255 June 2014 Rev A 12...
Страница 15: ...INITIAL START UP PN 30A255 June 2014 Rev A 15...
Страница 17: ...PREVENTIVE MAINTENANCE AND TROUBLESHOOTING PN 30A255 June 2014 Rev A 17...
Страница 20: ...CLEANING PN 30A255 June 2014 Rev A 20...
Страница 22: ...PN 30A255 June 2014 Rev A 22 FRYER OPERATION...
Страница 27: ...PN 30A255 June2014 Rev A 27 TECHNICAL ASSISTANCE ORDERING INFORMATION...
Страница 29: ...PN 30A255 June 2014 Rev A 29 RECOMMENDED SPARE PARTS...
Страница 31: ...PN 30A255 June 2014 Rev A 31 PARTS IDENTIFICATION...
Страница 34: ...PN 30A255 June 2014 Rev A 34 WIRING DIAGRAM...
Страница 35: ...PN 30A255 June 2014 Rev A 35...
Страница 36: ...PN 30A255 June 2014 Rev A 36 ACCEPTABLE ALTERNATE AND REQUIRED HI LIMIT CONSTRUCTION...