background image

CAUTION:  To reduce the risk of fi re or electrical 
shock, do not use this fan with any solid state speed 
control device.

Select the area you wish to cool.  Evaporative coolers 
work best near a partially opened door or window to 
draw in fresh air.  An equal amount of air should be 
discharged out of the room to dispel heat and humidity.  

Fill the reservoir from the back.  The reservoir holds 
5 1/2 gallons of water.   DO NOT OVER FILL.  Water 
will leak out and could cause water damage to the sur-
rounding area.  If the reservoir runs dry, it will not harm 
the pump.  When transporting the unit to a different 
location, be very careful not to spill the water.  It is best 
to re-locate the cooler, and then add water.  

Included is a fl oat for continuous fi ll.  To attach the 
fl oat, remove the back grille.  Remove the nuts from 
the fl oat and insert the fl oat into the water shield and 
then through the hole in the housing.  Secure the fl oat 
with the nut that was removed.  You may connect ei-
ther a 1/4 inch hose or a garden hose using the garden 
hose adapter.  Adjust the fl oat so that the water level is 
about an inch below the top of the reservoir.  Reinstall 
the back grille.

Plug the electrical cord into a 115-120 volt grounded 
outlet.  You may operate your cooler on one of three 
speeds: low, medium or high.  Turn the switch knob 
clockwise to activate the pump and fan.  This will cool 
the air.  Turn the switch counterclockwise to operate 
the cooler as a fan only (pump will be off).

Unpack your cooler and install the casters.  Slip the 
stems of the casters into the holes provided in the bot-
tom of the front and back grille.

CAUTION:  To reduce the risk of fi re, always unplug 
the cooler before attempting service of any kind.

No oil or lubrication is necessary.  The motor is perma-
nently lubricated at the factory.

No oil or lubrication is necessary.  Clean any debris 
from under the pump in the inlet area.

Remove the fi lter from the rear grille and rinse with 
water.  Be careful not to damage the fi lter!  The fi lter 
should be replaced every two years or if it becomes 
clogged.

Drain and clean the water tank.  To drain, remove the 
back grille and disconnect the clear hose from the 
black tube.  Turn unit on cool and pump out most of 
the water.  Wipe dry and clean with a towel.  Before 
reattaching the back grille, reconnect the clear hose to 
the black water tube.

CAUTION:  Always unplug the cooler before attempt-
ing service of any kind.

POSSIBLE CAUSE/REMEDY:

1. The pump hose may have worked loose.  Check the 
connection at the pump and at the water tube located 
in the back grille assembly.  Reconnect pump hose if 
necessary.

2. The water tube may be blocked.  Remove the tube 
and clean it out. Make sure water holes are clear.

3. The pump or switch may be defective.  Replace 
pump or switch, if necessary.

POSSIBLE CAUSE/REMEDY:

1. Verify there is 115-volt power at the electrical outlet.  
Check the fuse or breaker.

1. The fan switch or motor may be defective.  Replace 
if necessary.

PROBLEM:

Cooler Does 

Not Pump 

Water

PROBLEM:

Fan Does Not 

Operate

This warranty is extended to the original purchaser 
only.  It does not cover damages incurred during 
shipping or through accident, neglect, or abuse by the 
owner.  Essick Air Products/Champion Cooler does not 
authorize any person or representative to assume any 
other or different liability in connection with this cooler.

All original parts provided by Essick Air Products/
Champion Cooler are warranted against defects in 
material or factory workmanship for one year.

Essick Air Products/Champion Cooler is not respon-
sible for incidental or consequential damage resulting 
from any malfunction.

Essick Air Products/Champion Cooler is not respon-
sible for any damage occurring from the use of water 
softeners, chemicals, de-scale material, or if a higher 
horsepower motor is used in the unit other than what 
Essick Air Products recommends.

Essick Air Products/Champion Cooler is not respon-
sible for the cost of service calls to diagnose cause of 
trouble, or labor charge to repair and/or replace parts.

Contact the Dealer where you purchased the evapora-
tive cooler.  If for any reason you are not satisfi ed with 
the response from the Dealer, contact the Customer 
Service Department:  Essick Air Products, 5800 
Murray Street, Little Rock, Arkansas 72209 or call 800-
643-8341.

Register your product online at:
www.essickair.com/eac/onlineregistration-eac.htm

Terms And 

Conditions 

Of Warranty

Exclusions 

From 

Warranty

How To 

Obtain 

Service 

Under This 

Warranty

Register 

Product

Motor

Pump

Filter

Water Tank

MAINTENANCE

LIMITED WARRANTY

TROUBLE SHOOTING

EVAPORATIVE COOLER 

OPERATION

REPLACEMENT PARTS LIST
LISTA DE PIEZAS DE RECAMBIO

MOTOR

RED

BLACK

BLUE

WHITE

4

WHITE /

RIBBED

(COMMON)

BLACK / 

SMOOTH

(HOT)

PUMP

3

2

A

B

1

RIBBED

SUPPLY

SMOOTH

115V

GREEN

3 SPEED

SWITCH

GREEN (GROUND)

WIRE NUT OR
CRIMP TERMINAL

DE 115V

MOTOR

BLANCO

AZUL

NEGRO

ROJO

4

NEGRO / LISO

BOMBA

2

3

1

LISO

VERDE

ACANALADO

INTERRUPTOR DE

3 VELOCIDADES

B

A

ABASTECIMIENTO

BLANCO /

ACANALADO

VERDE (TIERRA)

EMPALME PLASTICO

7

1 110822-4  Casters 

Ruedecilla

 

 

(4 req’d) 

(4 req’d)

2 110845-22 Front 

Grille 

Rejilla 

Anterior

3 110850-2  Reservoir 

Depósito 

De 

Agua

4 110846-2  Fan 

Blade 

Hoja 

De 

Ventilador

5 110438 

Pump 

Bomba

224135-001 

Pump Mount 

Soporte De La Bomba

7 110441-4  Motor 

Motor

110394-2 

Power Cord 

Cable De Corriente

9 110849-2  Handle 

Asidero

10 110845-24  Knob 

Perilla

11 110425-1 

Switch 

Interruptor

12 310718-1 

Hose 

Manga

13 110588-1 

Tube 

Tubo

14 

110721 

Tube Cap 

Tapa Del Tubo

15 

155001-14 

Pad Retainer 

Soporte De Filtros

 

 

(2 req’d) 

(2 req’d)

16 

110121-1 

Poly Pad 

Filtro De Poliester

17 110122-1 

Media 

Medio 

Evaporativo

18 110845-21  Back 

Grille 

Rejilla 

Posterior

19 FL-C 

Float 

Flotador

20 

110852 

Water Shield 

Salpicadero del Flotador

21 110824 

Garden 

Hose  Adaptador 

para

 

 

Adapter 

Manguera De Jardín

No. Part 

No. 

Description 

Descripción

WIRING DIAGRAM

ESQUEMA DE CABLEADO

Before 

Operation

Fill Reservoir

Float 

Installation

Operation

Содержание M150

Страница 1: ...ir com 110489 1 3 10 Read Save These Instructions Manual De Instrucción Felicitaciones en su compra de esta enfriador Es el mejor enfriador que su dinero puede comprar El diseño único de este enfriador evaporativo móvil le provea dos características Primero convierte el aire caliente y seco a una brisa refrescante Segundo puede ser utilizado como ventilador para circular el aire cuando hay demasia...

Страница 2: ... dry and clean with a towel Before reattaching the back grille reconnect the clear hose to the black water tube CAUTION Always unplug the cooler before attempt ing service of any kind POSSIBLE CAUSE REMEDY 1 The pump hose may have worked loose Check the connection at the pump and at the water tube located in the back grille assembly Reconnect pump hose if necessary 2 The water tube may be blocked ...

Страница 3: ... Agua 4 110846 2 Fan Blade Hoja De Ventilador 5 110438 Pump Bomba 6 224135 001 Pump Mount Soporte De La Bomba 7 110441 4 Motor Motor 8 110394 2 Power Cord Cable De Corriente 9 110849 2 Handle Asidero 10 110845 24 Knob Perilla 11 110425 1 Switch Interruptor 12 310718 1 Hose Manga 13 110588 1 Tube Tubo 14 110721 Tube Cap Tapa Del Tubo 15 155001 14 Pad Retainer Soporte De Filtros 2 req d 2 req d 16 1...

Страница 4: ...nga en marcha la unidad a COOL y bombee fuera la mayoría del agua Limpie seco con una toalla Reconecte la manguera clara al tubo negro de agua antes de reconectar la rejilla posterior Motor Bomba Filtro Depósito De Agua CONSERVACIÓN FUNCIONAMIENTO DEL ENFRIADOR EVAPORATIVO Antes De Funcionar ADVERTENCIA Siempre desconecte el enfriador antes de procurar cualquier tipo de servicio CAUSA POSIBLE REME...

Отзывы: