REVA_040412
2
About the Lift Chair Service Guide
This service guide provides you with the information necessary to repair the UltraComfort 3-position,
2-position, and Stellar recline lift chairs. The troubleshooting scenarios in this manual consist of
procedures that enable you to systematically trace and correct faults in the system, replacement
procedures, and exploded views of available parts. Most replacement instructions apply to all the lift
chairs in this service manual, but some of them are specific to individual chairs.
Before troubleshooting, check the following:
• Make sure that the lift chair is plugged into a working wall outlet.
• Check the wall outlet circuit breaker.
• Visually check terminals for corrosion.
• Check wires for missing insulation.
• Check connectors for unseated pins.
• Ensure LED lights are on. (Refer to “Trouble Shooting with
SMART TEK
” on page 19).
Information required prior to making a service call:
• Serial Number
• Date of Purchase
• Description of the problem with the lift chair
Lift Chair Components
Lift chairs are powered by 24V DC transformers that plug into standard wall outlets and operate on
standard 120V AC electricity. The lift chair control system is made up of the following components:
• Motor(s)
• Hand Control
• Extension Wire
• Transformer
• Battery Backup Wire*
• Heat Unit*
• Massage Unit*
• Control Unit*
• Junction Box*
*Only on selected models
Component:
Motor
Location:
Between the lift frame and the seat.
Function:
Provides lift and recline.
Connections:
Each motor is physically connected to the chair through the lift frame and the recline
straps. Each motor is electrically connected to either a control unit or directly to the hand control.
Failure Signs:
Chair will not lift and/or recline. Motor may become noisy just before failure.
Tests:
See “Trouble Shooting with
SMART TEK
” on page 19.
Expected Readings:
See “Trouble Shooting with
SMART TEK
” on page 19.
Serviceable:
Must
be replaced.
Component:
Hand Control (Lift/Recline or Recline Only)
Location:
On the arm of the chair.
Function:
Provides user interface for lift/recline or recline only.
Connections:
Connected to either the control unit or the motor.
Failure Signs:
Chair will not lift and/or recline.
Tests:
See “Trouble Shooting with
SMART TEK
” on page 19.
Expected Readings:
See “Trouble Shooting with
SMART TEK
” on page 19.
Serviceable:
Must be replaced.
Содержание Leisure UC211
Страница 1: ...SERVICE GUIDE http waterheatertimer org pdf ...
Страница 25: ...REVA_040412 24 LM5000C LIFT MOTOR See parts list for specific hand control part number GM1500 LM LM RS5100 ...
Страница 28: ...REVA_040412 27 LM5100 LIFT MOTOR See parts list for specific hand control part number LM RS5100 GM1500 LM ...
Страница 31: ...REVA_040412 30 See parts list for specific hand control part number LM RS5100 GM1500 LM ...
Страница 33: ...REVA_040412 32 For use in models UC540M 26 See parts list for specific parts by model RB6111 1 LM RS5100 ...