- 32 -
Appendix A – Timer Manual
Timer Manual
Program Mode
1.
Enter the Program mode by holding down the “P” key for 3 seconds.
2.
Press the “P” key to move the top display from one parameter to the next.
3.
Press the “E” key to scroll the bottom display through the available choices for that parameter.
4.
While in Program mode the unit will stop timing and the output will retain its last state. The new settings
will only become effective after returning to Operation mode by holding down the “P” key for 3 seconds.
5.
If there is no key activity for 60 seconds, the unit will automatically return to Operation mode and maintain
the previous settings.
Operating Function
: Determines how outputs will operate in relation to the set value.
•
On Delay (OndL)
•
Off Delay (OFdL)
Factory setting
•
Interval (int)
•
Repeat Cycle (CYCL)
•
Delay/Interval (dint)
Time Range Indicator
Illuminates to show the time base: H
for hours, M for minutes, and S for
seconds. Multiple indicators will be
illuminated when the time base is
Hours:Minutes or Minutes:Seconds.
Set Value
Settable value used to trigger the
timed output.
Numeric Keys
Each of the number keys is used to
increment the value of the
corresponding digit of the preset or
a parameter value.
I/O Status Indicators
Illuminates to display when an input
or output is active: “IN” for the start
input, “OUT” for the timed output
and “RST” for the External reset
signal.
Time Indicators
The word “Timing” flashes when a timing
function is taking place. The applicable
arrow also lights to indicate if the display is
set to time up or time down.
Time Value
Indicates the elapsed/remaining time to
preset.
Edit Key
Many of the parameters in Program mode require
selection of a specific choice as opposed to a
numeric value. The Edit key is used to scroll
through the available choices. In Operation mode
the Edit key can be pressed simultaneously with
the Program key to rest the timer.
Program Key
Pressing the key continuously for 3 seconds moves
the unit in and out of Program mode. Once in
Program mode, pressing and releasing the key will
scroll the display from one parameter to the next.