Waste Pipe Installation
Run the waste hose to either an up stand or outside drain, a minimum air gap of 20mm
must exist at the end of the drain line. Softened water will have no adverse effect on a
septic tank. Should you need to extend the drain hose this can be for a maximum run of 8
meters with a minimum daytime pressure of 40 psi. Ensure that the drain hose is not
kinked or obstructed in any way as this will lead to an overflow of the softener.
The drain pipe can run uphill to a max of 1 meter with a min water pressure of 40 psi
Overflow Connection
The overflow connection is the white ½” hose spigot on the rear or side of the cabinet. The
overflow must be run downhill through an outside wall without kinks or restrictions. It is
recommended the overflow hose be visible when it exits the outside wall.