Parts And Assembly
Positioning The Softener
Where possible the softener should be placed close to the rising main. Take care to allow
hard water take off points for a drinking water facility and /or an outside tap.
The distance between the drain and the softener should be as short as possible. Ensure
that both the drain and overflow will not freeze or reach a temperature above 40°C. If
putting the softener within a cupboard ensure that the base is adequately supported. If
the softener is being installed within your loft etc it is recommended to house the softener
within a tank capable of storing at least 100 litres with an overflow fitted. The overflow on
the tank should be below the softener overflow and be a minimum of ¾” in size.
Single Check Valve
A suitable check valve should be fitted. This is usually inside the installation kit that can be
ordered separately at
https://ultra-soft.co.uk/product/water-softener-installation-kits/
Before you start the installation make sure that you have all the necessary fittings. The
purchase of one of our standard installation kits will normally ensure that you have
everything that you need for a typical installation.