background image

 

- 7 - 

 

 

ULT33063 

 
 
 

 
 
 
 
 
 
 
 

 
 

Battery Replacement Procedure 

5.3 Storage 

To store the UPS, cover it and store it with the battery fully charged. During extended 
storage, it is suggested to connect the utility power to the UPS to recharge the battery every 
three months to ensure battery life. 

 

A

PPENDIX A 

T

ROUBLESHOOTING

 

 

Problems Possible 

Cause 

Solution 

Full-time Bypass 
Protection outlets 
stop providing 
power to the 
equipment 

Circuit breaker button popped up as 
a result of overload. 

Unplug at least one piece of 
equipment from the Full-time 
Surge Protection outlets, 
switch off the UPS, wait for 5 
seconds and reset the circuit 
breaker (press down breaker 
button, then switch on UPS). 

Battery undercharged or depleted 
due to frequent power outages. 

Recharge the battery by leaving 
the UPS plugged in and switched 
on. 

The power required by your 
equipment slightly exceeds the 
capacity of the UPS. 

Unplug at least one piece of 
equipment from the UPS outlets.

UPS doesn’t 
perform to its 
expected runtime. 

The battery is slightly worn-out. 

Consider replacing the battery. 

UPS has a circuit breaker designed 
to prevent damage. 

Switch UPS off, wait for 5 
seconds, and then switch UPS 
on. 

The battery is worn-out. 

Consider replacing the battery. 

UPS cannot be 
turned on. 

 

Mechanical problem. 

Contact your sales 
representative. 

 

- 8 - 

A

PPENDIX B 

S

PECIFICATIONS

 

 

Part No.

ULT33063

Model

RCD-UPS700  

UPS Capacity

700VA

Total Capacity 
(Protection) 

1200VA 

No. of sockets 

Style A UPSx3, Bypassx3 

Voltage (on battery) 

Simulated sine wave at 120V +/- 5% 

Frequency(on battery) 

50 or 60Hz +/- 0.3Hz 

Output 

Transfer Time 

2-4 milliseconds, including detection time 

Voltage (single phase) 

120V +15%/-20% at line input 

Input 

Frequency   

50 or 60Hz +/- 10% (auto sensing) 

Unit Input 

Circuit breaker for overload & short circuit 
protection 

Overload Protection 

AC Mode: If load exceeds 110% of nominal, 
Buzzer beeps continuously. If load exceeds 
120% of nominal for 30 seconds, 130% for 3 
seconds, UPS shuts down automatically. 
Back up Mode: If load exceeds 105% of 
nominal for 20 seconds, 120% for 10 seconds, 
130% for 3 seconds, UPS shuts down 
automatically. 

Short Circuit 

UPS output 

shuts o

ff immediately  

Protection 

Surge Protection 1140 Joules, 2ms 

Type 

Sealed, maintenance-free lead acid batter

y

with 3-6 years typical lifetime 

Typical Recharge Time 

6 hours (to 90% of full capacity) 

Back-up Time   

9-11 minutes (a PC with 15” CRT monitor) 
17-19 minutes (a PC with 15” LCD monitor) 

Battery 

Protection 

Automatic self-test, Over

 

discharge 

protection, short circuit protection by fuse 

Net weight Kg (lbs) 

2.58(5.67) 

Physical 

Dimension (W x D x H) 

104 x 316 x 85 (4.1” x 12.4” x 3.3”)       

Interface USB 

Battery low detecting, USB on/off scheduling 
AC input/output power status display. 

Battery Back-Up 

Slow beeping sound every 4 seconds 

Battery Low 

Rapid beeping sound every second 

Charge Abnormal 

AC Mode: Rapid beeping sound every 0.5 
second 

Alarm 

Overload 

Continuous beeping sound 

Ambient operation 

3,500 meters max. elevation, 0-95% humidity 

non-condensing, 0-40

 

Environment

Audible Noise 

<40dBA (1 meter from surface) 

 