Chapter 5: Operating Instructions
Configure
Part No. 24001157
VersaMux-4000 Operation & Installation Guide
Page 5-23
Revision C
Copy-Config
The
Copy-Config
parameter enables you to copy the values of a configuration.
This is very useful if you want to create a new configuration similar to an existing
one.
describes the
Copy-Config
parameter options and actions.
Fiber-Timing
NOTE:
This parameter only appears in Software Versions 2.18 (DNE Part Number
25400645-011) and greater.
The
Fiber-Timing
parameter only has an affect when the Mode parameter is set to
Fiber-FOM
.
This parameter controls the timing reference
of the transmit 23.552
MHz timing when the port is operated in Fiber-FOM mode. The options are:
CTM
- Use this option when the remote equipment is a Codem CTM-100C.
Standard
- Use this option when the remote equipment is a device other than a
Codem CTM-100C (for example, a MD-1272, GSC-54, CV-FOM, CV-HTU-16M, etc.).
Table 5-6
Port Parameter and Option Descriptions
Parameter
Options and Description
Table 5-6
(page 3 of 3)
Table 5-7
Copy-Config Options and Descriptions
Option
Description of Action When Selected
No
The system will not copy the configuration nor make any changes.
Active
The system copies all of the active configuration parameter values to the offline
configuration.
Undo
When you activate an offline configuration, the system stores the previous
configuration in “undo.” When you select
Undo
the system copies the configuration
stored in undo to the offline configuration.
For example, if you have an original active configuration that you replaced by
activating the offline configuration, you can restore the original configuration by
selecting
Undo
.