background image

Decoupler calibration

1.  Access the correct decoupler at the back of 

the Material Station

4.  Hold the slider down, but do not compress the 

spring. Confirm with the eject button

3.  Confirm by pressing one of the eject buttons

2.  Push the slider of the decoupler all 

the way down, into the spring. You will 

feel some resistance

Note:  

Ensure you have access to both the front and the back of 

the Material Station.  

The calibration is performed on the decoupler at the back, and 

each step is confirmed by pressing an eject button at the front. 

Note:  

Keep the Bowden tube in the specified position until you have 

pressed the eject button.

Note:  

It does not matter which of the eject buttons you press 

to confirm each step.

Note:  

The Material Station will flash 

two times

.

5.  Pull the slider up, but do not compress the 

spring. Confirm with the eject button

Note:  

The Material Station will flash 

three times

.

Note:  

The Material Station will flash 

four times

.

6.  Pull the slider up as far as possible. 

You will feel some resistance

Confirm the last step by pressing one of the eject 

buttons. If the calibration was successful, the 

Material Station frame lights will stay on.

Note:  

If the Material Station goes back to flashing just once during 

this procedure, the input was unsuccessful. The procedure will 

start over from step 1.

Position 2

 

Free down

Position 1

 

Tension down

Position 3

Free up

Position 4

Tension up