Decoupler calibration
1. Access the correct decoupler at the back of
the Material Station
4. Hold the slider down, but do not compress the
spring. Confirm with the eject button
3. Confirm by pressing one of the eject buttons
2. Push the slider of the decoupler all
the way down, into the spring. You will
feel some resistance
Note:
Ensure you have access to both the front and the back of
the Material Station.
The calibration is performed on the decoupler at the back, and
each step is confirmed by pressing an eject button at the front.
Note:
Keep the Bowden tube in the specified position until you have
pressed the eject button.
Note:
It does not matter which of the eject buttons you press
to confirm each step.
Note:
The Material Station will flash
two times
.
5. Pull the slider up, but do not compress the
spring. Confirm with the eject button
Note:
The Material Station will flash
three times
.
Note:
The Material Station will flash
four times
.
6. Pull the slider up as far as possible.
You will feel some resistance
Confirm the last step by pressing one of the eject
buttons. If the calibration was successful, the
Material Station frame lights will stay on.
Note:
If the Material Station goes back to flashing just once during
this procedure, the input was unsuccessful. The procedure will
start over from step 1.
Position 2
Free down
Position 1
Tension down
Position 3
Free up
Position 4
Tension up