4.  Lift each of the hinges out of the mounting 

bracket, then place the hood aside

3.  To remove the transparent hood, press the little 

clip on either side of the mounting bracket

Tip:

 This clip locks the hood in place. Use your fi ngernail or a 

screwdriver to push it in for step 4.

Remove the fi lter housing

5.  Firmly grip the mounting bracket and place your 

thumbs in the notches of the fi lter housing

Tip:

 Keep the clip pressed while lifting the hinge. Do 

this one side at a time.

Tip:

 Push back against the mounting bracket while pushing the 

fi lter housing forwards. 

2.  Disconnect the Air Manager cable at the bottom 

of the fi lter housing

Tip:

 You can leave the cable in the stress relief for easier access when 

installing the replacement fi lter housing assembly.

1.  Remove the fi lter from the housing by pulling 

the tab at the front towards you

5.  Firmly push the fi lter housing forwards to detach 

it from the mounting bracket

Note:

 This requires some force. The fi lter housing will come loose 

with a loud snapping sound; this is normal.

Tip:

 The used fi lter should be handled with care; there is a risk of 

the ultrafi ne particles being released. Place the used fi lter in a 

(resealable) bag and close it.