2
Ultimaker S5 Air Manager
Repair manual: Air Manager fan
Ultimaker Customer Service instructions
4. Lift each of the hinges out of the mounting
bracket, then place the hood aside
3. To remove the transparent hood, press the little
clip on either side of the mounting bracket
Tip:
This clip locks the hood in place. Use your fi ngernail or a
screwdriver to push it in for step 4.
Remove the fi lter housing
5. Firmly grip the mounting bracket and place your
thumbs in the notches of the fi lter housing
Tip:
Keep the clip pressed while lifting the hinge. Do
this one side at a time.
Tip:
Push back against the mounting bracket while pushing the
fi lter housing forwards.
2. Disconnect the Air Manager cable at the bottom
of the fi lter housing
Tip:
You can leave the cable in the stress relief for easier access when
installing the replacement fi lter housing assembly.
1. Remove the fi lter from the housing by pulling
the tab at the front towards you
5. Firmly push the fi lter housing forwards to detach
it from the mounting bracket
Note:
This requires some force. The fi lter housing will come loose
with a loud snapping sound; this is normal.
Tip:
The used fi lter should be handled with care; there is a risk of
the ultrafi ne particles being released. Place the used fi lter in a
(resealable) bag and close it.