8

Tighten threaded connections. 

Inspect other appliances near water heater.

Turn on electrical switch. Check for blown

fuses or tripped breaker.

Reset. Check for source of trouble and correct.

Replace thermostat.

Replace thermostat.

Replace thermostat.

Set thermostat to desired temperature.

Drain. Determine if water treatment is needed.

Install adequate water heater.

Correct piping.

Repair faucets.

Review and reduce hot water consumption.

Insulate piping.

Insulate piping.

Replace thermostat.

Set thermostat to desired setting.

Drain. Flush-Provide water treatment if needed.

Install adequate heater.

Correct piping.

Repair faucets.

Review and reduce hot water consumption.

Insulate piping.

Insulate piping.

Replace element.

Use Pressure Reducing Valve and Pressure 

Relief Valve.

See “Thermal Expansion” in the For Your Infor

-

mation section.

Replace thermostats.

Replace thermostats.

See “Operational Conditions” in the For Your 

Information section.

Contact dealer to clean or replace elements.

 

problem 

possible cause(s) 

corrective action

 

 

 

 

These guidelines should be utilized by a qualified service agent. 

trouBleshootinG Guidelines

Improperly sealed, hot or cold supply connection, 

relief valve or drain valve.

 

Leakage from other appliances or water lines. 

No power to heater.

High Temperature Limit Switch open.

Non-functioning thermostat.

Non-functioning thermostat.

Improper calibration.

Thermostat set too low.

Sediment or lime in tank.

Heater too small for job.

Wrong piping connections.

Leaking faucets.

Wasted hot water.

Long runs of exposed pipe.

Hot water piping on outside wall.

Improper Calibration.

Thermostat set too high.

Sediment or lime in tank.

Heater too small for job.

Wrong piping connections.

Leaking faucets.

Wasted hot water.

Long runs of exposed piping.

Hot water piping in exposed wall.

Non-functioning element.

Excessive water pressure.

Closed system.

Non-functioning thermostats.

Improper calibration.

Sulfides in the water.

Scale accumulation on elements.

water  leaKs

    (see  leakage  checkpoints  in  this  manual)

no  hot  water

insufficient  hot  water

hiGh  operation  costs

slow  hot  water  recoverY

drip  from  relief  valve

thermostat  does  not  shut  off

water  odor

water  heater  sounds

Содержание 2.5 Gallon 120 volt water heater

Страница 1: ... BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED IF YOUARE UNSUCCESSFUL PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER LISTED Instruction Manual RESIDENTIAL ELECTRIC 2 5 GALLON 120 VOLT WATER HEATER FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING http waterheatertimer org How to install under counter water heater html ...

Страница 2: ...S Qualified Installer A qualified installer must have ability equivalent to a licensed tradesman in the fields of plumbing and electrical installation of these appliances This would include a thorough understanding of the requirements of the National Electrical Code and applicable local electrical and plumbing codes and tools necessary to confirm proper installation and operation of the water heat...

Страница 3: ... GENERAL SAFETY ...

Страница 4: ...ter heater INSTALLATION OR SERVICE OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED PLUMBING AND ELECTRICAL WORK ARE REQUIRED Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this manual 5 For California installation this water heater must be braced anchored or strapped to avoid f...

Страница 5: ...abled If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap then you must take special precautions In addition to using the lowest possible temperature setting that satisfies your hot water needs a means such as a mixing valve should be used at the hot water taps used by these people ...

Страница 6: ...d by a leak detector or water shut off device used in conjunc tion with a piped drain pan These devices are available from some plumbing supply wholesalers and retailers and detect and react to leakage in various ways Sensors mounted in the drain pan that trigger an alarm or turn off the incoming water to the water heater when leakage is detected Sensors mounted in the drain pan that turn off the ...

Страница 7: ...t against the bracket FIGURE 3A MOUNTING FLOOR 1 The floor selected must be capable of supporting double the weight of the unit when completely full of water 77 Ibs 2 The installation area must provide adequate clearances for removal of the front panel and servicing the unit 3 Place a suitable drain pan under the unit The pan must limit the water to a maximum depth of 2 1 2 inches and be 2 inches ...

Страница 8: ...d systems do not allow for the expansion of heated water The water within the water heater tank expands as it is heated and increases the pressure of the water system If the relieving point of the water heater s temperature pressure relief valve is reached the valve will relieve the excess pressure The temperature pressure relief valve is not intended for the constant relief of thermal expansion T...

Страница 9: ...flow may cause property damage The Discharge Pipe Shall not be smaller in size than the outlet pipe size of the valve or have any reducing couplings or other restrictions Shall not be plugged or blocked Shall be of material listed for hot water distribution Shall be installed so as to allow complete drainage of both the temperature pressure relief valve and the discharge pipe Shall terminate at an...

Страница 10: ...10 WIRING DIAGRAM FIGURE 5 ...

Страница 11: ...liar with the electric codes and practices or if you have any doubt even the slightest doubt in your ability to connect the wiring to this water heater obtain the service of a competent electrician Contact a local electrical contractor and or the local electric utility WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY This water heater is equipped for one type voltage only Check the rating plate near th...

Страница 12: ...r temperatures be used to avoid the risk of scalding It is further recommended in all cases that the water temperature thermostat be set for the lowest temperature which satisfies your hot water needs This will also provide the most energy efficient operation of the water heater KEEPING THE THERMOSTAT SETTING AT 120 F 49 C OR LOWER WILL REDUCE THE RISK OF SCALDS Figure 6 shows the approximate time...

Страница 13: ...n the water heater this harmless bacteria is nontoxic to humans D An excess of active hydrogen in the tank This is caused by the corrosion protective action of the anode Smelly water may be eliminated or reduced in some water heater models by replacing the anode s with one of less active material and then chlorinating the water heater tank and all hot water lines Contact the local water heater sup...

Страница 14: ...od sacrifices itself to protect the tank Instead of corroding the tank water ions attack and eat away the anode rod This does not affect the water s taste or color The rod must be maintained to keep the tank in operating condition NOTE Artificiallysoftenedwaterismorecorrosivebecausetheprocess substitutes sodium ions for magnesium and calcium ions The use of a water softener may decrease the life o...

Страница 15: ...n or replace it 1 Turn off and unplug the water heater from the electrical outlet and follow DRAINING INSTRUCTIONS 2 Remove the front panel see the REMOVING THE FRONT PANEL section in this manual Remove the insulation pad 3 Remove the two screws from the mounting bracket see Figure 10 being careful not to drop the screws into the unit as they will be difficult to retrieve Remove bracket and set sc...

Страница 16: ...or replacing the element in ELEMENT CLEANING REPLACEMENT High Limit Switch Removal and replacement 1 Turn off and unplug the heater from the electrical outlet 2 Remove the front panel see the REMOVING THE FRONT PANEL section in this manual Remove the insulation pad Remove personnel barrier 3 Remove the four wires connected to the switch taking care to note the original placement of each wire 4 Usi...

Страница 17: ...ater on the side of the tank may be condensation due to the panel or insulation not being in place E Water in the water heater bottom or on the floor may be from condensation loose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances water lines or ground seep...

Страница 18: ...blem Possible Cause s Corrective Action These guidelines should be utilized by a qualified service agent TROUBLESHOOTING GUIDELINES Improperly sealed hot or cold supply connection relief valve or drain valve Leakage from other appliances or water lines No power to heater High Temperature Limit Switch open Non functioning thermostat Non functioning thermostat Improper calibration Thermostat set too...

Страница 19: ... number of your Water Heater will be found on the rating plate located above or adjacent to outer door WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION MODEL NUMBER SERIAL NUMBER VOLTAGE AND ELEMENT WATTAGE PART DESCRIPTION THIS IS A REPAIR PARTS LIST NOT A PACKING LIST figure 13 1 Element Gasket 2 Anode Rod 3 Element Assembly with Gasket Anode Fasteners 4 High Limit with Personnel...

Страница 20: ...20 ...

Отзывы: