Water supply systems may, because of such events as high line
pressure, frequent cut-offs, the effects of water hammer among others,
have installed devices such as pressure reducing valves, check valves,
back flow preventers, etc. to control these types of problems. When
these devices are not equipped with an internal by-pass, and no other
measures are taken, the devices cause the water system to be closed.
As water is heated, it expands (thermal expansion) and closed systems
do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated and
increases the pressure of the water system. If the relieving point of
the water heater’s temperature-pressure relief valve is reached, the
valve will relieve the excess pressure.
the temperature-pressure
relief valve is not intended for the constant relief of thermal
expansion.
This is an unacceptable condition and must be corrected.
It is recommended that any devices installed which could create a
closed system have a by-pass and/or the system have an expansion
tank or device to relieve the pressure built by thermal expansion in
the water system. Expansion tanks are available for ordering through
a local plumbing contractor. Contact the local water heater supplier
or service agency for assistance in controlling these situations.
stranGe sounds
Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not necessarily
represent harmful or dangerous conditions.
operational conditions
water odor
In each water heater there is installed at least one anode rod (see
parts sections) for corrosion protection of the tank. Certain water
conditions will cause a reaction between this rod and the water.
The most common complaint associated with the anode rod is one
of a “rotten egg smell” in the hot water. This odor is derived from
hydrogen sulfide gas dissolved in the water. The smell is the result
of four factors which must all be present for the odor to develop:
A. A concentration of sulfate in the supply water.
B. Little or no dissolved oxygen in the water.
C. A sulfate reducing bacteria which has accumulated within the
water heater (this harmless bacteria is nontoxic to humans).
D. An excess of active hydrogen in the tank. This is caused by the
corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater
models by replacing the anode(s) with one of less active material,
and then chlorinating the water heater tank and all hot water lines.
Contact the local water heater supplier or service agency for further
information concerning an Anode Replacement Kit and this chlorination
treatment. If the smelly water persists after the anode replacement and
chlorination treatment, we can only suggest that chlorination or aeration
of the water supply be considered to eliminate the water problem.
do not remove the anode leaving the tank unprotected. By doing
so, all warranty on the water heater tank is voided.
“air” in hot water faucets
HYDROGEN GAS: Hydrogen gas can be produced in a hot water
system that has not been used for a long period of time (generally
two weeks or more). Hydrogen gas is extremely flammable and
explosive. To prevent the possibility of injury under these conditions,
we recommend the hot water faucet, located farthest away be opened
for several minutes before any electrical appliances which are
connected to the hot water system are used (such as a dishwasher
or washing machine). If hydrogen gas is present, there will probably
be an unusual sound similar to air escaping through the pipe as the
hot water faucet is opened. There must be no smoking or open
flame near the faucet at the time it is open.
hiGh water temperature shut off sYstem
A non-adjustable high temperature limit control operates before
steam temperatures are reached. The high limit switch must be reset
manually when it operates. BECAUSE THE HIGH LIMIT OPERATES
ONLY WHEN ABNORMALLY HIGH WATER TEMPERATURES
ARE PRESENT, IT IS IMPORTANT THAT A QUALIFIED
SERVICE AGENT BE CONTACTED TO DETERMINE
THE REASON FOR OPERATION BEFORE RESETTING .
•
Turn off and unplug the water heater. Do not attempt to reset
thermostat with power on.
• Remove the front panel, see “Removing Front Panel” in the
Periodic Maintenance section.
• Remove the insulation to expose the reset button.
• Reset the high limit by pushing in the red button.
• Replace the insulation so that it completely covers the thermostat
and element.
• Replace the front panel.
• Plug in and turn on the water heater.