8.

 

The maximum total head (Hmax) of the pump (in metres) shown on the pump label should 

be noted by the installer. 

9.

 

The permissible temperature is + 0

  

and - 40

.  The pump should never be operated 

outside of these temperatures, to do so could cause damage. 

 

 

ELECTRICAL CONNECTION 

 

Check that the information on the nameplate corresponds to the power supply. 

Employ a competent electrician to ensure wiring installation is made in accordance with any local 

electrical codes. Every motor requires either a fused disconnect switch or a circuit breaker. 

A SINGLE PHASE MOTOR has a built in thermal overload switch. 

 

PUMP WATER PRIMING 

 

The pump will prime and re-prime providing the pump basket area is full of water and there is 

sufficient supply from the suction point. If you lose water from the pump basket area it will be 

necessary to re-fill it before starting. 

1.

 

 Remove the translucent lid and fill the pump basket with water. 

2.

 

Replace the lid ensuring that the O ring is correctly located and start the pump. 

After you have done this allow a few minutes (maximum) running for the pump to re-prime. If 

this fails then simply repeat the priming procedure. 

 

WARNING: 

 

Mechanical seals will be rapidly damaged and may need replacing if the pump is run dry – this 

is not a warranty condition. 

 

ENSURE that there is always adequate water in the pump basket before you start up. 

If you are unable to prime the pump, please see the trouble shooting guide. 

ENSURE that all suction and discharge valves are open before you start the pump, avoiding 

resultant damage to the pump. 

 

MAINTENANCE 

 

The strainer basket in the pump should be inspected and cleaned at regular intervals. 

1.

 

 Remove lid and lift out basket. 

2.

 

 Remove debris and hose off with clean water if necessary. 

3.

 

Inspect the lid gasket, lubricate with SILICON based grease such a magic lube, only if needed.   

4.

 

Replace the strainer. 

5.

 

Re-prime the pump basket area. 

6.

 

Correctly locate the O-ring. 

7.

 

Replace the lid (hand tighten only). 

8.

 

Switch on the pump. 

In climates where the pump may be exposed to frost or freezing, care must be taken to ensure 

the pump is protected from frost damage. 

It is recommended that if the pump is not used during winter periods it should be drained 

completely and stored in a dry location. Do not replace the drain plug but store it in a safe place 

when not in use; for example, the pump basket.  

 

Содержание UKPS16

Страница 1: ...are designed to work with water at temperatures above 0 C and below 45 C The filter should never be operated outside of these temperatures or damage may occur 2 The installation should be carried out in accordance with the safety instructions for swimming pools and the specific instructions for each facility 3 The user must ensure sure that the installation is carried out by qualified authorised p...

Страница 2: ...t Valve and back through the swimming pool piping system Preparation before installation 1 Position the filter as close to the Swimming Pool Spa as possible 2 The filter should be placed on a level concrete slab very firm ground or the equivalent Ensure that the ground will not subside preventing any strain on the attached plumbing 3 Position the filter so that it does not compromise the piping co...

Страница 3: ...into the filter 6 Carefully pour the sand into the filter vessel Ensure that no sand enters the stem pipe and that no damage occurs to the laterals Continue filling the filter until the correct charge has been installed see chart for sand fill charges 7 Remove the Top Hat and wash any debris off the filter top mount put the O Ring on the top mount multiport valve and with a twisting pushing action...

Страница 4: ... impurities and fine sand particles evident in the filter media 6 Turn pump OFF and set valve to RINSE position Turn pump ON and run until the water in sight glass is clear about to 1 minute Turn pump OFF set valve to FILTER position and restart pump Your filter is now operating in the normal filter mode filtering particles from the pool water and returning fresh clean water back into your pool NO...

Страница 5: ...E Rinse RINSE After backwashing and with pump OFF set valve to RINSE Start pump and operate for about to 1 minute This ensures that all dirty water from backwashing is rinsed out of the filter to waste preventing possible return to the pool Stop pump set valve to FILTER and start pump for normal filtering Waste WASTE To bypass the sand filter for draining or lowering water level and for vacuuming ...

Страница 6: ...ufacturer or its service agent or a similarly qualified person 10 The pump must be supplied through a residual current device RCD having a rated residual operating current not exceeding 30mA 11 Children should be supervised to ensure that they do not play with the appliance 12 The pump must be protected from running dry LOCATION The pump must be located as close as is practical to the pool The pum...

Страница 7: ...mp to re prime If this fails then simply repeat the priming procedure WARNING Mechanical seals will be rapidly damaged and may need replacing if the pump is run dry this is not a warranty condition ENSURE that there is always adequate water in the pump basket before you start up If you are unable to prime the pump please see the trouble shooting guide ENSURE that all suction and discharge valves a...

Страница 8: ...tem clean lines skimmer and pump basket check pump impeller for blockage Motor will not run No power to motor Check that all electrical switches are on Ensure the circuit breakers are properly set Check if timer is properly set Check motor wiring at the terminals Pump jammed With power switched off turn pump shaft should spin freely Low Flow Dirty Filter Backwash or clean cartridge Dirty skimmer a...

Страница 9: ... at motors should be no more than 6 above or below nameplate voltage Have electrician check voltage ensure pump is not running on an extension cord Report low supply to authorities Overload due to binding Contact Supplier in pump or wrong size impeller WARNING If the pump is within the stated warranty period and you experience faults always contact your supplier Failure to do this may void warrant...

Отзывы: