- 2 -
2.Specifications
【 Standard specifications 】 Table.1
Item
Specifications
M
e
a
s
u
r
e
m
e
n
t
Mesurement accuracy
(accumulate)
Scaling(Conversion instrument)± 0 to the 1
(At the time of correction display current position and function
stop)
Total display
Upper tier:6 Digits red color LED character height10mm
PV display(Measured value) Middle tier:6 Digits red color LED character height10mm
SV display(Target value) Lower tier:6 Digits red color LED character height8mm
CH display
Lower tier:6 Digits red color LED character height8mm
Analog input display
ANA Lamp Lighting (orange 3φLED)
Control signal display
RUN Lamp Lighting (green 3φLED)
Slow down signal display SLW Lamp Lighting (green 3φLED)
End signal display
END Lamp Lighting (green 3φLED)
Normal stop display
STP Lamp Lighting (green 3φLED)
Deviation error display STS Lamp Lighting (red 3φLED)
Measurement error display ALM Lamp Lighting (red 3φLED)
Manual state display
MAN Lamp Lighting (orange 3φLED)
Measurement display
Range
TOTAL
0~999999
more than 999999 was flashing display
(Non-zero suppression)
PV
(Measured alue)
SV Setting of range
Target value 0~999999
Scaling(Conversion value) 1×10
-9
– 9999 (selectable)
Decimal point
Displays 1 - 3 decimal points. (selectable)
PV display reset
Use the start key or start signal for reset, start of surveying
from 0.
(Selection when reset start)
Keep reset key is ON for more than two seconds
Terminal block is ON for more than 100mS
Over run correction
Compensation beyond the value from SV value (Target value)
(Arbitrarily set the be stopped value before In 00000~99999 of
SV value.)
Sonsor input
anomaly detection
If there is no input of set number of pulses in the set time、
Outputs the abnormal signal measurement, Measurement abnormal
display lights(ALM),batch control stop.
S
e
n
s
o
r
Input signal
NPN Open Collector pulse, Or input voltage pulse.
(Setting can be switched in DIP SW)
Input level
NPN Open Collector pulse: MIN 10mA or more(Sink current)
Voltage pulse:LOW Level 2.0V or lower HI Level 3.8~30V
Input response
LOW:0.01Hz~50Hz HI:0.01Hz~10kHz
However, when duty 50%
Sensor power
Standard DC+12V(±10%)100mA MAX(Stabilization)
Option
DC+24V(±10%) 60mA MAX
S
i
g
n
a
l
Reset signal
Terminal block input is ON for more than 100ms
NPN Open Collector output,accept short output
PVdisplay reset and Release error
Sink current:more than MIN 10mA
Start signal
Stop signal
Abnormality signal
Ban signal
Terminal block input is ON for more than 100ms
NPN Open Collector output,accept short output
Sink current:more than MIN 10mA