- 25 -
Mode No. Current display position correction・setting of the measurement operation
P-05
A B C D E F
P - 0 5
G H I J K L
0 0
Measurement operation
0:The usual measuremen
1:Measurement, only while a control signal is
outputting.
Current display position correction
0:Functional stop
1:Display position correction
〔Current display position correction〕
A current position is rectified to a target position after the end of batch
control.
<Caution> TOTAL indicated value is not rectified.
〔setting of the measurement operation〕
You want to measure a flow only while the control signal is outputting,
please set up "Measurement, only while a control signal is outputting." ("1")
Only while a control signal is outputting, TOTAL display and PV display also
measures a flow.
Mode No. Setting of input anomaly detection
P-06
A B C D E F
P - 0 6
G H I J K L
0 2.0 0 0
The number of anomaly detection pulses
01~99(00 is functional stop)
Anomaly detection time
00.1~19.9 sec
(00.0 = 20.0 sec)
・Release of a measurement abnomal signal is reset and a stop
(a key and a terminal box) are turned on.
〔input Anomaly detection〕
If there is no input of a number of pulses (the number of anomaly detection
pulses) set up within the set-up time (anomaly detection time), a measurement
unusual signal will be outputted, batch control is suspended, and a measurement
abnormality display (ALM) lights up.
<The example of a setting>
If there is no input for 10 pulses for 5 seconds after starting measurement,
it will suppose that an input is unusual and will output a measurement unusual
signal.
A B C D E F
P - 0 6 H.I:5.0(For 5 seconds after a measurement start)
G H I J K L
5.0 1 0 K.L:1 0(10-pulse or more input)