Relay

EXIT BUTTON

PWR

B

U

ZZ

E

R

-

+

4

MAIN COMPONENTS

Components

Manufacturer

MCU

STM8S003F3

Linear Regulator

SPX117-3.3

RF Transceiver Chip

SYN500R 

SYNOXO

ST
SIPEX

Relay

G5Q

OMRON

OPERATING SETTINGS

10   5   0

Relay

RF-KEY

T

L
M

EXIT BUTTON

3

2

1

4

1. Lock Mode Select

NO: Fail-Secure Lock 
NC: Fail-Safe Lock

2. Operating Mode Select

T: Toggle
L: Latched
M: Momentary

3

.

T

 

ime Delay Select

Support 0/5/10 seconds locking delay 

time, default is 5 seconds.

4

.

T

 

ransmitter Paring

Press the RF-KEY on the receiver once,

 

and the indicator on it will flash green 

once. Then press the button on the 

transmitter within 20 seconds, the 

LED indicator on the receiver will 

flash green three times to indicate 

the paring is successful.

5

.

C

 

lear Code

Press and hold the RF-KEY for 

8 seconds until the indicator 

changes from green to red.

4

PWR

B

U

ZZ

E

R

-

-

+

+

NC

LOCK

COM

NO

10   5   0 RF-KEY

T

L
M

LOCK

COM

NO

-

+

NC

NO

NO

Model

Содержание HBK-R01

Страница 1: ...REMOTE CONTROL SWITCH USER MANUAL Model HBK R01...

Страница 2: ...rofessional electrician as it requires specialized knowledge Incorrect operation may damage the product or make it inoperable The transmitter and receiver have been paired with each other in factory K...

Страница 3: ...er are not included Built in diode real time protecting relay door lock and buzzer prolonging the service life MAIN FEATURES SPECIFICATIONS Receiver Operating Voltage 12VDC Frequency 433MHz Operating...

Страница 4: ...ched M Momentary 3 Time Delay Select Support 0 5 10 seconds locking delay time default is 5 seconds 4 Transmitter Paring Press the RF KEY on the receiver once and the indicator on it will ash green on...

Страница 5: ...ON PWR BUZZER NC LOCK NO NO Relay PWR BUZZER T L M 10 5 0 RF KEY COM EXIT BUTTON LOCK NO NC NO WIRING DIAGRAM V V PUSH TO EXIT 1 When connect Fail Secure Lock 2 When connect Fail Safe Lock V V PUSH TO...

Страница 6: ...NSTRATION DIAGRAM 1 When connect Fail Secure Lock Note Exit button access keypad buzzer lock and power adapter are only for demonstration purpose which are not included Fail Secure Lock 6 V V NO COM S...

Страница 7: ...MONSTRATION DIAGRAM 2 When connect Fail Safe Lock Fail Safe Lock Note Exit button access keypad buzzer lock and power adapter are only for demonstration purpose which are not included 7 V V NO COM Swi...

Страница 8: ...al 3 Q Why can t the lock work properly when the wiring is correct A Please check whether the indicator of the receiver is on and the mode of lock is selected correctly For more details please refer t...

Страница 9: ...io communications However there is no guarantee that interference will not occur in a particular installation I f this equipment does cause harmful interference to radio or television reception w hich...

Страница 10: ...Focus on the access control system industry making home security within reach We Create Security...

Отзывы: