Uhlmann TBOX COMPETITION Скачать руководство пользователя страница 2

 

The remaining three LEDs are arranged one above the other on the right side and signal the 
measuring results of the individual measuring (measuring LED). When testing the cable, 
each LED corresponds to a wire in the cable. 
 
To switch the device on in battery mode, press and hold the button. The device switches on 
automatically, if voltage is supplied through the micro USB socket. An optional  power 
supply unit (ref. 13620-2) is available for this purpose. Of course, any other 5V USB power 
supply unit can be used. Micro-USB connection cables are optionally available (LN5589). 
When the device will be switched on, a self-test will be carried out. If this is successful, all six 
LED light up white. 
The status of the battery is indicated by the measuring LED in battery mode. 
Three measuring LED green -> battery OK 
Two measuring LED yellow -> battery weak 
One measuring LED red -> battery very weak 
If the battery is very weak, it should be replaced or the device should be supplied with 
voltage via the micro-USB connection. The device can be used, even if the battery is very 
weak. However the battery can become too weak at any time (three red flashing mode LED) 
and can no longer be used. 
 
In battery mode, the device is automatically switched off after 30 seconds of inactivity. To 
switch off the device manually, hold the button down until all three mode LED are off. As 
soon as you release the button, the device is switched off. If the device is supplied with 
voltage via USB, it always remains switched on and is always ready for use. 

 

Check mode 1: Epee

 

 

Connect the epee to a body cord on the right side of the tester. Press the button on the 
device and hold it down until the left mode LED lights up red. Release the button now. The 
upper measuring LED signals the resistance of the epee wire. The LED lights up green for a 
resistance <= 3.0 Ohm 
yellow for a resistance between 3.1 ohms and 5 ohms 
red for a resistance between 5.1 ohms and 10 ohms.  
The LED does not light up if the resistance is > 10.0 Ohm.  
In addition, a resistance <= 3.0 ohms is indicated by an acoustic signal. To test the insulation 
of the tip / wire to the blade / guard, hold down the tip contact of the weapon and bend the 
blade in all directions. If the lower measuring LED lights up red, there was a short connection 
between the tip / wire and the blade / guard. This signaling remains visible until the 
measurements are reset by briefly pressing the button. Even the shortest connections can be 
discovered and signaled. 

 

 
 
 

Содержание TBOX COMPETITION

Страница 1: ...ht RBG LED are available to signal the test mode and the measuring results Measuring results are partly given by an acoustic signal The device has a Kensington lock device and it can be stored theft p...

Страница 2: ...shing mode LED and can no longer be used In battery mode the device is automatically switched off after 30 seconds of inactivity To switch off the device manually hold the button down until all three...

Страница 3: ...eck mode 3 Sabre Connect a saber to a body cord on the right side of the tester The crocodile clip for connecting the vest can be attached to the conductive fabric part at the top of the device Press...

Страница 4: ...he LED light up green for a resistance 3 0 Ohm yellow for a resistance between 3 1 ohms and 5 0 ohms red for a resistance 5 0 Ohm Micro interruptions are also indicated by a red LED The worst signaled...

Страница 5: ...r on the test accessory Press the button on the device and hold it down until the left mode LED lights up blue Release the button now The three measuring LED indicate the resistance of the three wires...

Страница 6: ...t ref 13620 2 to a mains supply at a voltage of 100 240 V 50 Hz The devices should only be connected to the electricity supply system after all cables have been installed For absolutely safe disconnec...

Страница 7: ...anpower Defective power cord or socket The device has been exposed to moisture or rain Water has penetrated or an object has fallen into the device The device shows serious functional changes and is n...