Table of the Configuarion Variables
CV Addr.
Range 1
897
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
920
921
922
923
924
925
Factory
Setting
1
85
1
255
0
3
2
4
1
0
0
0
8
0
0
0
0
128
5
5
128
27
4
Description
SUSI address range
1 = from 900 to 925
2 = from 940 to 965
3 = from 980 to 1005
Manufacturer ID
Software version
Speaker volume
function activates sound "x" (x = value of the CV)
x = 0 no sound is produced
x = 1 bell or horn #1
x = 2 whistle or horn #2
x = 3 motor (driving) sound
x = 4 uncoupling or door warning sound
x = 8 fade in/out all sounds
f1 activates sound "x"
where "x" is defined as per CV903/943/983
f2 activates sound "x"
where "x" is defined as per CV903/943/983
f3 activates sound "x"
where "x" is defined as per CV903/943/983
f4 activates sound "x"
where "x" is defined as per CV903/943/983
f5 activates sound "x"
where "x" is defined as per CV903/943/983
f6 activates sound "x"
where "x" is defined as per CV903/943/983
f7 activates sound "x"
where "x" is defined as per CV903/943/983
f8 activates sound "x"
where "x" is defined as per CV903/943/983
f9 activates sound "x"
where "x" is defined as per CV903/943/983
f10 activates sound "x"
where "x" is defined as per CV903/943/983
f11 activates sound "x"
where "x" is defined as per CV903/943/983
f12 activates sound "x"
where "x" is defined as per CV903/943/983
Configuration
Wert
Bit 0 = 0 The "chuff" sound of a steam locomotive is
0 *
controlled by the locomotive speed. However,
if a sensor is present, its information shall be
automatically used in order to synchronize the
"chuff" to the wheels.
Bit 0 = 1 The "chuff" sound of a steam locomotive is
0 *
controlled only by the sensor.
Bit 7 = 0 The module sound power output stage is
0
always turned on.
Bit 7 = 1 The module sound power output stage is
128 *
turned off if the sound is turned off.
Threshold for the load-dependend sound generation by
increasing load: 128 = load-dependend sound generation is off
Threshold for the load-dependend sound generation by
decreasing load: 128 = load-dependend sound generation is off
Threshold for exhaust fan for electric locomotive
255 = no exhaust fan sound
Threshold for brake squeal sound
255 = no brake squeal
Sensitivy to load changes
1 = reacts very quickly / 8 = reacts very slowly
Allowable
Values
1-3
-
-
0-255
0-8
0-8
0-8
0-8
0-8
0-8
0-8
0-8
0-8
0-8
0-8
0-8
0-8
0, 1, 128,
129
0-128
0-128
0-255
0-255
1-8
CV Addr.
Range 2
897
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
960
961
962
963
964
965
CV Addr.
Range 3
897
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
1000
1001
1002
1003
1004
1005