background image

 

  

DAISY  

   

 

  

24

  

 

 

 

 5 

Special 

Options 

The DAISY Special Options can be edited using the DAISY 
“Programming mode”. 

 

Special 

Option 

Description 

Range Default

Software version number (cannot be edited!) 

DAISY serial number (cannot be edited!) 

0=turnout positions not saved (analog mode) 
1=turnout positions saved (analog mode) 

0-1 0 

11 

LED brightness while operating as a DAISY-System: 
0 = maximum brightness 
3 = minimum brightness 

0-3 0 

12 

LED brightness while operating as an add-on throttle: 
0 = maximum brightness 
3 = minimum brightness 

0-3 1 

13 

Dynamic effect (rotary encoder) for 28 and 31 speed steps 
locomotives: 
0 = off 
15 = maximum dynamic effect 

0-15 5 

15 

0= DAISY-System (digital) does not generate any Motorola signal
1= DAISY-System (digital) always generates a Motorola signal 

0-1 1 

16 

0= DAISY-System (digital) does not generate any DCC signal 
1= DAISY-System (digital) always generates a DCC signal 

0-1 0 

17 

Dynamic effect (rotary encoder) for 128 speed steps locomotives:
0 = off 
15 = maximum dynamic effect 

0-15 8 

23 

Maximum ‘on’ time for accessory decoders: 
0 = as long as the corresponding key is pressed 
1-15 = 0.3 through 2.3 seconds in equal steps 

0-15 4 

 

All Special Options can be reset to the factory settings by keeping the 
[Stop] key pressed while either turning on the DAISY-System or 
plugging the DAISY throttle into LocoNet. 

 

Содержание DAISY

Страница 1: ......

Страница 2: ...on Stefano Chiti Batelli with kind support by Mr Robert Frowenfeld Copyright Uhlenbrock Elektronik GmbH Bottrop Germany 1st English edition March 2003 All rights reserved Unauthorized reproduction inc...

Страница 3: ...Cables 26 1 4 Power 2 LED status 26 1 5 How to connect it 27 2 Booster use 27 3 Digital system use 3 1 How to connect a DAISY throttle 29 3 2 How to connect additional Boosters and LocoNet devices 29...

Страница 4: ...same layout Furthermore if all locomotives are of the DCC format it can also be used to control through locomotive address zero an analog locomotive a locomotive not equipped with a digital decoder Tu...

Страница 5: ...l etc and convert them to digital commands for DCC accessory decoders This allows for analog train operation and digital turnout signal control 1 2 Memory function As the power to the layout is turned...

Страница 6: ...oming from there If necessary one can branch LocoNet as required so as to allow for connection of more devices or throttles This can be done e g using our LocoNet multiple outlet box art Num 62 250 TI...

Страница 7: ...meter input during programming 3 Driving direction indicators triangular LEDs 4 Stop layout Power Off On toggle 5 Turnout key for activating turnout mode and for turnout signal ad dress selection 6 Pr...

Страница 8: ...e off key turns them on only as long as the off key remains pressed f1 through f4 In drive mode these keys allow controlling special functions F1 through F4 of the currently selected locomotive Pressi...

Страница 9: ...ing this locomotive selection process This is how to proceed Press the Locomotive key The display indicates Loco Release the Locomotive key The display indicates the currently selected locomotive addr...

Страница 10: ...t each locomotive address which is already stored in an other memory will be shown with all decimal points turned on and the DAISY will not accept any command to memorize that address again TIP DAISY...

Страница 11: ...ssing the Locomotive key or abort locomotive address editing by pressing either the Turnout or Prog keys TIP The 1st memory position can be edited however it cannot be erased 2 2 3 How to edit the loc...

Страница 12: ...to edit the current format type of a locomotive Press the Locomotive key The display indicates Loco Release the Locomotive key The display will show the currently selected locomotive address e g 7 Ro...

Страница 13: ...ry from which a device can read it later This is how to proceed Press and release the Locomotive key The display will show the currently selected locomotive address Press the Off key and keep it press...

Страница 14: ...n toggled will be shown as long as the key remains pressed For example the display will show W 2 the first symbol represents the letter W to indicate Weiche the German word for turnout While in turnou...

Страница 15: ...DAISY throttle is connected as an add on throttle to a LocoNet Command Station e g an Intellibox This is how to proceed While in turnout mode press the Turnout key The display will display the turnou...

Страница 16: ...ion which has been selected last Press the function key as required for the desired programming con figuration option to be shown Rotate the encoder to select the desired CV Register or Special Option...

Страница 17: ...he LocoNet connector of the last Power2 Each Power2 drives its own section of the analog layout electric circuit Each throttle connected to the LocoNet connector of the last Power2 can control any Pow...

Страница 18: ...rts circuit coupling Speed knob The speed knob can be used for controlling the locomotive speed Turning the speed knob clockwise increases locomotive speed while turning the speed dial counterclockwis...

Страница 19: ...off minimum acceleration deceleration delay f1 on f2 off low acceleration deceleration delay f1 off f2 on medium acceleration deceleration delay f1 on f2 on maximum acceleration deceleration delay No...

Страница 20: ...e mode to select a different locomotive This is how to proceed Press the Locomotive key The display indicates Loco Release the Locomotive key The display indicates the currently selected electric circ...

Страница 21: ...signal Press the Turnout key to switch from drive to turnout mode While in turnout mode you can use the f1 through f4 keys to toggle the status of a turnout or signal The four LEDs above the f1 throu...

Страница 22: ...tle can only be used for changing configuration parameters of the DAISY throttle itself This is how to proceed Press the Prog key The display indicates ProG Release the Prog key The display indicates...

Страница 23: ...n IB Control This is how to proceed Disconnect all devices from the Intellibox Connect the DAISY throttle with the LocoNet T connector of the Intellibox using a LocoNet cable Connect the Intellibox to...

Страница 24: ...der for 28 and 31 speed steps locomotives 0 off 15 maximum dynamic effect 0 15 5 15 0 DAISY System digital does not generate any Motorola signal 1 DAISY System digital always generates a Motorola sign...

Страница 25: ...DAISY 25 Power 2...

Страница 26: ...t voltage range adjustable 15 V 20 V Max power output current 2 A Max current output for LocoNet devices 300 mA Suggested transformer 16 V 45 VA LocoNet output with Booster signal 1 3 Cables Please us...

Страница 27: ...tput voltage can be adjusted in range 15V through 20V by using the small trimmer potentiometer labeled Ausgangsspannung Output Voltage The output voltage is about 15V when the trimmer is rotated fully...

Страница 28: ...need to be connected to a DAISY System then they can be connected either to the Booster connector or to the LocoNet connector In the latter case all additional Boosters must be connected directly to t...

Страница 29: ...gether using a LocoNet cable we will shortly describe how to do this Every throttle connected to LocoNet can take control of each electric circuit Power2 by using an automatically assigned identificat...

Страница 30: ...ed to the analog layout then the best solution is to add the new Power2 at the end of the existing daisy chain of Power2 s as this will not modify the automati cally assigned identification numbers of...

Страница 31: ...ing it this way it is possible to select the FRED number by using the f1 through f4 keys This number will determine which group of 4 Power2 s that FRED will be able to select FRED ID 1 electric circui...

Страница 32: ...een completed by pressing the function key in the target electric circuit before that another coupling process can be started once the locomotive has moved within the target electric circuit layout se...

Страница 33: ...Power2 s controlling a layout in analog mode to interpret the turnout signal commands issued through LocoNet by throttles or other devices e g IB Switch Switch Control etc and convert them to digital...

Страница 34: ...minimum delay means that a locomotive will react very quickly to speed changes f3 switching speed i e half speed f3 off normal speed f3 on switching speed half of normal speed f4 enable disable accele...

Отзывы: