C- INSTALLATION OF YOUR PRODUCT
Positioning
Possible placement positions:
1- In a way that the back side alone is opposite to the wall; be careful that there is a gap of 150 mm (15 cm)
between the wall and your device (Picture 6).
2- In a way that is place to a corner; when you place it to a corner, leave a gap of 150 mm (15 cm) behind. You
can lean the side, corresponding to the corner, to the wall.
The most important point to be considered in all cases of product placement is not to obstruct ventilation of
the compressor assembly.
Without exposing your product to any slope, place and operate it in a manner that it is on its feet or wheels.
The freer the compressor assembly ventilation is, the better the device will run.
PICTURE 6
15 c
m
In commercial products:
Climate Class of your product is indicated on the technical specification label on the product.
Climate Class
Temperature Range
Humidity
Class 3
25 °C
60% Rh
Class 4
30 °C
55% Rh
Class 5
40 °C
40% Rh
PICTURE 4