14
Arctic Compact 5-8
7. 3. 4 ASSEMBLY
1
Slide the drip tray into place.
2
Pinch tube faucet:
push the dispensing
handle (1) and insert the pinch tube into its
vertical seat in the bowl bottom(2). Lightly pull
the pinch tube end downwards til itl is well
arranged (3) (see figure 4).
figure 4
3
Gravity faucet
: install the faucet handle and
the piston with its gasket (see figure 5).
figure 5
4
Fit the bowl gasket to the evaporator. Note:
the largest brim of the gasket must face against
the drip plate (see figure 6).
figure 6
5
Place bowl on the unit. Wet the gasket for
ease of insertion.
Please take care that the hook on the backside
of the bowl be inserted properly in its seat on the
upper drip plate. (see figure 7).
figure 7
6
Use fresh product to chase any remaining
sanitizer from the bowl(s). Drain this solution. Do
not rinse out the machine.
7. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the
machine may be performed, if needed, only as
f u r t h e r p r e c a u t i o n , i n a d d i t i o n t o t h e
Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C,
120-140 °F) sanitizing solution (100 PPM
available chlorine concentration or 1 spoon of
sodium hypoclorite diluted with two litres of
water) according to your local Health Codes and
manufacturer’s specifications.
2
Pour the solution into the bowl(s).
3
Using a brush suitable for the purpose, wipe
the solution on all surfaces protruding above the
solution-level and on the underside of the top
cover(s).
4
Install the top cover(s) and operate the unit.
Allow the solution to agitate for about two
minutes. Drain the solution out of the bowl(s).
5
Use fresh product to chase any remaining
sanitizer from the bowl(s). Drain this solution. Do
not rinse out the machine.
8 ROUTINE MAINTENANCE
Daily:
inspect the machine for signs of product
leaks past seals and gaskets. If proper assembly
does not stop leaks around seals or gaskets,
check for improper lubrication, worn or damaged
parts. Replace parts as needed with original