10
Arctic Compact 5-8
1 ELECTRICAL SAFETY
INSTRUCTIONS
1
Before connecting the dispenser to the
mains, check that the voltage shown on the
rating plate matches your electricity supply.
Connect the dispenser to a single-phase supply
through an earthed socket as required by current
r e g u l a t i o n s . I f t h e d i s p e n s e r i s t o b e
disconnected from the power supply using a
single pole switch, the gap between the contacts
on this switch must be sufficiently wide to
guarantee full disconnection under category III
overload conditions.?
2
Do not use extension cables to connect the
appliance.
3
To avoid any risks, if the power cable is
damaged, it must be replaced by the
manufacturer, by an authorised technician or by
a similarly qualified person.
4
The dispenser is not suitable for outdoor use.
5
The dispenser must be installed in the
upright position.
6
Before cleaning, always disconnect the
dispenser by removing the plug from the socket.
7
Always disconnect the dispenser before
removing any of the panels for cleaning or
maintenance work.
8
Do not use a water jet to clean the dispenser.
9
This appliance must not be operated by
children.
10
Do not let children play with the appliance.
11
This appliance must not be used by persons
with reduced physical, sensory or mental
capabilities or with a lack of experience and
knowledge unless they have supervision or have
been trained regarding the safe use of the
appliance and understand the risks involved.
12
Only persons who know and have practical
experience of the appliance are permitted access
to the inner components of the dispenser,
especially when dealing with issues regarding
safety and hygiene.
2 HYGIENIC SAFETY
INSTRUCTIONS
1
This appliance is intended exclusively for
domestic and similar use.
2
For the appliance to operate correctly, room
temperature must be b5° and +32°C.
3
Use the appliance to cool the indicated
liquids only.
4
Do not introduce dangerous or toxic liquids
to the appliance.
3 TECHNICAL CHARACTERISTICS
Specifications are subject to change without
notice.
4 INTRODUCTION
It is necessary to read all sections of this manual
thoroughly to familiarize yourself with all aspects
of the unit.
Like all mechanical products, this machine will
1/5
1/8
2/5
2/8
3/5
3/8
4/5
4/8
Transparent removable bowls n
1
2
3
4
Capacity of each bowl, approx. l
5
8
5
8
5
8
5
8
Dimensions:
width
cm 18 25 37 50
depth
cm 40 40 40 40
height
5 lt
8 lt
cm 55
63
55
63
55
63
55
63
Net weight, approx.
5 lt
8 lt
kg
13
14
17
17
22
22
27
29
Gross weight, approx.
5 lt
8 lt
kg
14
15
18
19
24
24
29
30
Adjustable thermostats
n
1
1
1
2
Hermetic compressor
Air-cooled condenser
Overload protector
Noise level lower than 70 dB (A)
IMPORTANT
Read electrical ratings written on the data plate of
the individual units; the data plate is adhered on
the dispensing side panel of the unit, just behind
the drip tray (the right side drip tray in multiple
bowl models). The serial number of the unit
(preceded by the symbol #) is adhered just below
the right bowl. Data plate specifications will
always supersede the information in this manual.