background image

Page: 6 

< Librae instruction manual

Back to contents

Back to contents

Back to contents

 

1 General

Librae instruction manual >

 Page: 7

1 General  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

1.1 Principle of Operation

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

2 Instrument Description  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

2.1 Main Unit

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

2.1.1 Important Notice about Force Range

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

2.1.2 Animal Welfare

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

2.1.3 Touch-screen command/display

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

2.1.4 Notes on Resistive Touch-Pads

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

2.2 Animal Restrainer

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

2.3 Librae Features

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

3.1 Unpackaging & Preliminary Check

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

3.2 Note on the Instruction Manual

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

3.3 Safety Instructions

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

3.4 Assembling the instrument

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.5 Before Applying Power

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3.6 Intended Use

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3.7 Additional Safety Considerations

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3.8 Connection

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

4 Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

4.1 Home Page

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14

4.1.1 Quick setup for first test

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

4.1.2 System Icons

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

4.1.3 Home Page Icons

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

4.2 Experiment

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

4.3 Setup

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20

4.4 Start

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

4.5 Calibration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

4.6 Set Autostart

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

4.7 Utilities

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

4.7.1 Update

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

4.7.2 Date-Time

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

4.7.3 Advanced Settings

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

4.7.4 Erase DB

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

4.7.5 Results

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

4.7.6 USB Storage

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

4.8.1 Communication port connection

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

5 Maintenance   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

5.1 Electrical

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

5.2 Cleaning/disinfection

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

5.3 Long Inactivity

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

5.4 Customr Support

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

6 Specifications   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

Contents

1 General

The Librae Incapacitance Tester can be used for a number of applications that require animal 

weight bearing measurement (hind paw weight distributions). 

The most common application is for joint pain studies and

 

related drug candidates, especially 

for osteoarthritis.

1.1 Principle of Operation

The Librae Incapacitance Tester provides weight bearing measurement of restrained rats or 

mice, by using two force sensors, one per paw. These independently measure the paw weight 

over time (the weight averaged over a few seconds is normally used as the data point). 

For example, the device provides an index of discomfort in the osteoarthritic knee, normally 

expressed as the Left/Right weight ratio or Left/Right weight difference between the two paws. 

2 Instrument Description

The Instrument comprises:

•  The main unit, an original Ugo Basile design, see paragraph 2.1, incorporating the 2 force 

sensors, touch screen controls and a display screen for viewing data trends and results 

•  A Plexiglas restrainer for mouse or rat (or both depending on the model), see paragraph 2.2. 

•  A pedal switch to start the experiment (or use touch screen to start the experiment)

The Librae Incapacitance Tester provides data files (CSV) that can be transferred to a PC for 

analysis using a spreadsheet application such as Microsoft Excel.

Data is also saved automatically (e.g. left and right weights, L/R ratio, etc...) and can be retrieved 

using the touch screen.

2.1 Main Unit

The measurement plate on the unit is a 10mm aluminium slab, to ensure maximum thermal 

and mechanical stability.

High quality force sensors provide the measurement with a resolution of 0.1g. Foot pads are 

magnetically attached to make them easy to remove and clean after every experiment. The foot 

pads are flat without any physical protrusions that could cause negative effects on the comfort 

or gait of the animal.

Four rubber feet act as dampeners in order to absorb small vibrations from the work bench or 

the environment.

2.1.1 Important Notice about the Force Range

The maximum weight the instrument can carry is 2’200g per paw.

Applied forces that are greater than 2’200g per paw, will not be measured.

A mechanical limit switch, avoids a force overload greater than 4’400g.

Do not place animals weighing more than 5’000g on the Librae Incapacitance Tester to avoid 

causing any permanent damage to the instrument.

Содержание 47883

Страница 1: ...Instruction manual Librae Incapacitance tester July 2020 revision 2 2 SKU 47883 47882 47885 47880 001 Pain Inflammation...

Страница 2: ...organization Instruction Manual July 2020 Revision 2 2 MOD 13 Rev 1 CE CONFORMITY STATEMENT Manufacturer UGO BASILE srl Address Via G di Vittorio 2 21036 Gemonio VA ITALY Phone n 39 0332 744574 Fax n...

Страница 3: ...d of this manual and also at ugobasile com Product features What is in the box Librae package contents SKU 47883 The Librae Incapacitance tester for mice 1 transparent plastic restrainer for mice 1 Pe...

Страница 4: ...e the weight averaged over a few seconds is normally used as the data point For example the device provides an index of discomfort in the osteoarthritic knee normally expressed as the Left Right weigh...

Страница 5: ...th the Librae touch screen you may notice a different less sensitive response You may need to press slightly harder or use a stylus pen on the touch screen This is because we employ a resistive touch...

Страница 6: ...e you are welcome to contact our Service Department see paragraph 5 4 Customer Support specifying the serial number of your instrument 3 3 Safety Instructions The following guidelines must be followed...

Страница 7: ...e manufacturer Servicing carried out by unauthorized personnel See also paragraphs 2 1 1 and 2 1 2 3 8 Connection Connect the mains cord between the power socket of the Librae and the power outlet pro...

Страница 8: ...might take up to 60 seconds During this time the UB logo and product name will be displayed Figure 4 0 1 Figure 4 0 1 4 1 Home Page When the start up is finished the Home Page Menu is displayed Figur...

Страница 9: ...l has entered the restrainer tilt the restrainer back down to the flat position 8 When ready press START button or pedal switch to run the experiment 6 1 If Autostart Mode is enabled wait for the inst...

Страница 10: ...text field to enable a virtual keyboard Figure 4 2 2 This is an alphanumeric field enter a maximum of 12 characters Figure 4 2 2 Characters Virtual Keyboard Figure 4 2 3 Numeric Virtual Keyboard PROT...

Страница 11: ...the restrainer and if the experiment is running correctly Figure 4 4 1 Ehorizontal lements displayed on the START page from left to right provide the following functionality 1 i INFO button This butto...

Страница 12: ...start Autostart is a unique Librae Incapacitance Tester feature By selecting this operative mode Librae helps the user to perform the experiment in a consistent way reducing variability and user bias...

Страница 13: ...tabilization AUTO icon is YELLOW When ALL the autostart requirements are completed the experiment automatically starts Figure 4 6 5 Figure 4 6 5 Autostart is waiting for stabilization time to elapse A...

Страница 14: ...or update system icon refer to paragraph 4 1 1 5 Press Update button and wait for a reboot Figure 4 7 1 1 Now the Librae Incapacitance Tester is up to date An Erase DB could be necessary Refer to para...

Страница 15: ...ton shows Figure 4 7 5 1 the results of the experiments stored inside Librae Incapacitance Tester Every result box contains 1 Date and time of the experiment 2 Treatment ID protocol stage and trial 3...

Страница 16: ...gure 4 8 1 1 and Table 4 8 1 1 for connector pinout Figure 4 8 1 1 DB 15 Pin Signal Name Signal Type Description 1 Start Stop TTL OUT Start TTL High Level Stop TTL Low Level 2 Manual Autostart TTL OUT...

Страница 17: ...not hesitate to contact our service department or our local distributor either directly of via our support page Before sending any instrument to our factory for repair please contact our logistics dep...

Страница 18: ...paratus Thermal Place Preference TPP Test for Mice Rats Analgesy Meter the 1st and original Randall Selitto paw pressure test Other Ugo Basile products related to this device visit ugobasile com web s...

Страница 19: ...torio 2 21036 Gemonio VA ITALY Tel 39 0332 744574 sales ugobasile com The 1st original Mouse RotaRod for motory coordination studies Fear Conditioning System ANYmaze GSM Grip Strength Meter for mice a...

Отзывы: