S9300-32D Hardware Installation Guide | 23
Figure 31.
2.6
Use a heat source to secure the heat shrink tubing in place. Allow the heat shrink tubing
to cool before attaching the DC power cable. An example of the installed DC version with
insulation material as below.
Figure 32.
3.
Attach the power cable.
Locate the DC power screw-type terminal block located on the PSU. Remove the plastic cover
that is protecting the terminal block by pushing from the top or bottom of the cover and
flipping open the cover outwards (Top picture). Secure the one-hole lug (with the DC power
cable attached) to the terminal block (Middle picture). Put plastic cover back on terminal block
to guard against contact with terminals (Bottom picture).