background image

14

IRT807

OFF

ZERO

kHz

Temp

SMOOTH

mV

mA

INSULA

TION

V

V

50V

1000V

INSULATION TESTER

Apo

MIN/MAX

LOCK

Hz

Test Voltage

F  C

SELECT

TEST

RANGE

PI/DAR

A-HOLD

0

0.1 M

1 M

10 M

100 M

1 G

2 G

V

DC

   M

IRT807

Apo

m

A

•  Default   =  

mA

•  Press x1 =  

mA

SELECT

mAmps AC/DC

 WARNING

Never connect the test leads across 

(in parallel with) a voltage source 

when attempting to measure current. 

This can cause damage to the circuit 

under test or this meter. 

Note:

 

To measure current, you must 

create a break in the circuit under test 

and make the meter part of the circuit. 

Two connection points are created when a 

circuit is broken. On one side is the power 

source and the other is the load.

Features:  

 

SELECT

 

MIN/MAX

 

Test Voltage

F  C

RANGE

 

LOCK

A-HOLD

Hz

PI/DAR

AC and DC CURRENT

RANGE

RESOLUTION

ACCURACY

AC (45Hz to 1000Hz)

40mA

0.01mA

±(1.5% +5 dgts)

1

400mA

0.1mA

DC

40mA

0.01mA

±(0.5% +5 dgts)

400mA

0.1mA

1. 1kHz bandwidth

Overload Protection 440mA, 1000V, FAST fuse

IRT807

OFF

ZERO

kHz

Temp

SMOOTH

mV

mA

INSULA

TION

V

V

50V

1000V

INSULATION TESTER

Apo

MIN/MAX

LOCK

Hz

Test Voltage

F  C

SELECT

TEST

RANGE

PI/DAR

A-HOLD

0

0.1 M

1 M

10 M

100 M

1 G

2 G

V

DC

   M

IRT807

Apo

m

A

Frequency

RANGE

RESOLUTION

ACCURACY

99.99Hz

0.01Hz

±(0.1% +3 dgts)

999.9Hz

0.1Hz

9.999kHz

0.001kHz

99.99kHz

0.01kHz

Sensitivity: >AC 1V RMS, >AC 10mA

The meter measures the frequency of 

a voltage or current signal by counting 

the number of times the signal crosses a 

threshold level each second. To measure 

Frequency, set selector dial Volt or Milliamp 

position. In the mA position, press the

 

SELECT button

 to select AC, if needed. 

Press the 

PI/DAR button

PI/DAR

•  Default   =  

mA

Features: 

 

LOCK

A-HOLD

Hz

PI/DAR

MIN/MAX

Test Voltage

F  C

RANGE

SELECT

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание IRT807

Страница 1: ...STER Apo MIN MAX LOCK Hz Test Voltage F C SELECT TEST RANGE PI DAR A HOLD 0 0 1M 1M 10 M 100 M 1 G 2 G VDC M INSTRUCTION MANUAL ENGLISH IRT807 1000V AC DC Digital Insulation Resistance Tester www Glob...

Страница 2: ...328 to 2462 F 200 to 1350 C 11 Resistance 12 Continuity 12 Diode Test 13 Capacitance 13 mAmps AC DC 14 Frequency 14 Earth bond Resistance 15 Insulation Resistance 1000V 500V 250V 100V 50V 16 Measuring...

Страница 3: ...emperature 14 to 122 F 10 to 50 C Operating Humidity 75 Operating Altitude 6 526 ft 2000m Pollution Degree 2 Over range OFL is displayed Backlight Yes Refresh Rate 3 sec Dimensions 8 27 x 3 52 x 2 17...

Страница 4: ...ment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current...

Страница 5: ...e test Continuity SMOOTH INSULATION 50V 1000V Insulation Test mV DCmV PI DAR Polarization Index Dielectric Absorption Ratios mA Milliamp AC DC Auto HOLD ZERO ZERO Greater Than HOLD Auto power off acti...

Страница 6: ...gory Max Indicator Maximum CAT Rating for input jacks Use CATIII test leads or higher Zero Test Lead Port Fused used for Zero Ohms and mA Common Test Lead Port Volt Insulation Test Lead Port CATIV 600...

Страница 7: ...er under protective rubber boot Q Serial Number under kick stand Default Press x1 k Voltage 1000V AC IRT807 OFF ZERO kHz Temp SMOOTH mV mA INSULATION V V 50V 1000V INSULATION TESTER MIN MAX LOCK Hz Te...

Страница 8: ...y generated by frequency motor drives and inverters WARNING Use CATIII rated Test leads or higher Do not attempt to measure more than 1000V AC Keep hands below finger guards when measuring high voltag...

Страница 9: ...es MIN MAX Test Voltage F C RANGE LOCK A HOLD SELECT DC MILLIVOLTS RANGE RESOLUTION ACCURACY 400mV DC 0 1mV 0 2 3 dgts Temperature 328 to 2462 F 200 to 1350 C Fahrenheit is the default temperature mea...

Страница 10: ...PI DAR A HOLD 0 0 1M 1M 10 M 100 M 1 G 2 G VDC M IRT807 Apo Default Press x1 Press x2 Press x3 SELECT IRT807 OFF ZERO kHz Temp SMOOTH mV mA INSULATION V V 50V 1000V INSULATION TESTER Apo MIN MAX LOCK...

Страница 11: ...C RANGE CAPACITANCE RANGE RESOLUTION ACCURACY OVERLOAD PROTECTION 10 00nF 0 01nF 2 5 5 dgts 600V 100 0nF 0 1nF 1 000 F 0 001 F 10 00 F 0 01 F 100 00 F 0 1 F 1000 F 1 F 3 5 dgts 10000 F 1 F WARNING Ca...

Страница 12: ...AC 45Hz to 1000Hz 40mA 0 01mA 1 5 5 dgts 1 400mA 0 1mA DC 40mA 0 01mA 0 5 5 dgts 400mA 0 1mA 1 1kHz bandwidth Overload Protection 440mA 1000V FAST fuse IRT807 OFF ZERO kHz Temp SMOOTH mV mA INSULATION...

Страница 13: ...ect if the circuit is energized 5 The dashes will display until the TEST Button is pressed and a valid resistance value is detected 6 The High Voltage symbol will display if greater than 2V AC DC is p...

Страница 14: ...ust be connected in parallel to the circuit or circuit element under test Set Rotary dial to INSULATION and press RANGE button to select desired voltage The display will show until the button is press...

Страница 15: ...unction dial to INSULATION position and press RANGE button to select desired voltage Press the PI DAR button to select PI or DAR The display shows until TEST button is pressed and a valid resistance i...

Страница 16: ...A 1000V 1R 10kA Replace the battery cover Replace the protective rubber boot Fuse AA battery AA battery AA battery AA battery Fuse AA battery AA battery AA battery AA battery Removed protective rubber...

Страница 17: ...ive from such defects the unit will be repaired or replaced at UEi s option This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration...

Отзывы: