8
• Short the ends of the test leads together, press the
SELECT button
and wait until
ZERO
appears. The meter measures the
test leads resistance, stores the data/results in memory and subtracts it from the reading. The test lead resistance is saved
even after the meter is powered off.
• The display will show “----” until a valid resistance reading is detected.
• The High Voltage symbol will display if greater than 2V AC or DC is present. If the meter “chirps”when you press the
TEST button
, test is corrupted due to voltage being present.
• Press and hold the
TEST button
on the Meter or Remote Probe to start test. Test stops when the button is released.
Features:
TEST
SELECT
LOCK
NOTE:
When the resistance is higher than the maximum display range the tester displays the > symbol and the maximum
resistance for the range.
WARNING
NEVER test resistance on a live circuit. (Overload Protection: AC 2V rms or DC)
RANGE
RESOLUTION
ACCURACY
20.00Ω
0.01Ω
±(1.5% +3)
200.0Ω
0.1Ω
2000Ω
1Ω
20.00kΩ
0.01kΩ
1. Accuracies apply from 0 to 100% of range
2. Open Circuit Test Voltage: > 4.0V, < 8V
3. Short Circuit Current: > 200.0 mA
Earth-Bond Resistance <20kΩ