DISPOSAL

 CAUTION:

  

This symbol indicates that equipment and its accessories shall be subject to separate collection and correct 

disposal.

CLEANING

Periodically clean your meter’s case using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong detergents 

as they may damage the finish, impair safety, or affect the reliability of the structural components.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. 

After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the 

instrument to return to normal operating conditions before using it.

WARRANTY 

The IRT803 is warranted to be free from defects in materials and workmanship for a period of 1 year from the date of 

purchase. If within the warranty period your instrument should become inoperative from such defects, the unit will be 

repaired or replaced at UEi’s option. This warranty covers normal use and does not cover damage which occurs in shipment 

or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries 

and consequential damage resulting from failed batteries are not covered by warranty. 
Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular 

purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or 

consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic 

loss. 
A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered. 

Instruments out of warranty will be repaired (when repairable) for a service charge. 
For more information on warranty and service, contact: 

This warranty gives you specific legal rights. You may also have other rights, which vary from state to state.

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание IRT803

Страница 1: ...TESTER 600V CAT IV 600V CAT III 1000V COMPARE LOCK PI DAR TEST SELECT HOLD 0 0 1M 1M 10M 100M 1G 20G Apo VDC INSTRUCTION MANUAL ENGLISH IRT803 1000V AC DC Digital Insulation Resistance Tester www Glo...

Страница 2: ...20k 8 Continuity 9 Insulation Resistance 1000V 500V 250V 100V 10 Polarization Index Dielectric Absorption Ratio 1000V 500V 250V 100V 11 Compare Function 12 Test Lead Notes 12 Testing the Fuse 13 Test...

Страница 3: ...V 600V CATIII 1000V IP42 RoHS 6 Drop Protection IEC EN 61010 1 2010 Battery Type AA 4 Test Leads Silicone test leads w alligator clips red and black ATL57 Remote Probe Accuracy of reading of least sig...

Страница 4: ...ment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current...

Страница 5: ...r Than PI DAR ZERO 30 Segment Bargraph Ground Measurement Category Short Circuit typical kAa Location in the building installation II 10 Circuits connected to mains socket outlets and similar points i...

Страница 6: ...esistance test and PI PAR test Also used for testing the fuse H Function Dial Turns on meter and is used to select the function I Category Max Indicator Maximum CAT Rating for input jacks Use CATIII t...

Страница 7: ...ection AC 1000V rms or DC O Kick Stand For easy viewing of screen when testing P Battery and Fuse Cover under protective rubber boot Q Serial Number under kick stand IRT803 OFF ZERO ZERO FUSED V COM I...

Страница 8: ...t test Test stops when the button is released Features TEST SELECT LOCK NOTE When the resistance is higher than the maximum display range the tester displays the symbol and the maximum resistance for...

Страница 9: ...OLD Apo V Continuity Features HOLD WARNING Do not measure resistance continuity on a live circuit Beeper sounds constant as long as circuit is complete Beeper sounds when a short 40 is detected RANGE...

Страница 10: ...GE RESOLUTION TEST CURRENT ACCURACY 100V 0 to 20 0 01 to 20 00M 0 01M 1mA 100k 3 5dgts 20 0 to 100 0M 0 1M 250V 0 to 20 0 01 to 20 00M 0 01M 1mA 250k 1 5 5dgts 20 0 to 200 0M 0 1M 500V 0 to 20 0 01 to...

Страница 11: ...OCK PI DAR TEST Because of the time required for the PI and DAR tests alligator clips are recommended Use rotary selector dial to select desired test voltage The display will show until test starts Th...

Страница 12: ...Lead Notes CATIV 600V Measurement Locations Ensure the test lead shield is pressed firmly in place Failure to use the CAT IV shield increases arc flash risk CAT II Measurement Locations CAT IV shield...

Страница 13: ...ly test the batteries Turn the rotary selector dial to the Battery Voltage position with no test leads connected Press the Select button to start the battery test The battery voltage is displayed for...

Страница 14: ...ve rubber boot Remove protective rubber boot Remove battery cover Replace the fuse F 440mA 1000V 1R 10kA Replace the battery cover Replace the protective rubber boot Removed protective rubber boot Rem...