background image

•  To zero the manometer, press and 

hold the DIF ZERO button for 4 

seconds.

•  The display will show ‘8888’ to 

indicate that the Zero function 

has occurred.

DISPOSAL

 CAUTION:

  

This symbol indicates that equipment 

and its accessories shall be subject to separate collection 

and correct disposal.

FCC/IC INFORMATION

FCC STATEMENT
This equipment has been tested and found to comply with 

the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful 

interference in a residential installation. 
This equipment generates, uses and can radiate radio  

frequency energy and, if not installed and used in  

accordance with the instructions, may cause harmful 

interference to radio communications. However, there 

is no guarantee that interference will not occur in a 

particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be 

determined by turning the equipment off and on, the user 

is encouraged to try to correct the interference by one or 

more of the following measures:
 •  Reorient or relocate the receiving antenna.
 •  Increase the separation between the equipment  

  and receiver.
 •  Connect the equipment into an outlet on a circuit  

  different from that to which the receiver is connected.
 •  Consult the dealer or an experienced radio/TV  

  technician for help.
This equipment complies with FCC RSS102 radiation  

exposure limits set forth for an uncontrolled environment.
FCC NOTICE
This device complies with Part 15 of the FCC rules and 

Industry Canada license-exempt RSS 247. Operation is  

subject to the following two conditions: (1) This device may 

not cause harmful interference; and (2) this device must 

accept any interference received, including interference 

that may cause undesired operation.
FCC CAUTION
The device must not be co-located or operated in  

conjunction with any other antenna or transmitter.
Caution the user that changes or modifications not  

expressly approved by the party responsible for  

compliance could void the user’s authority to operate  

the equipment.

CLEANING

Periodically clean your meter’s case using a damp cloth. DO NOT 

use abrasive, flammable liquids, cleaning solvents, or strong 

detergents as they may damage the finish, impair safety, or affect 

the reliability of the structural components.
Keep pressure ports clean and free of grease and other deposits; 

clean with a moist cloth as required.

STORAGE

Remove the battery when instrument is not in use for a prolonged 

period of time. Do not expose to high temperatures or humidity. 

After a period of storage in extreme conditions exceeding the 

limits mentioned in the General Specifications section, allow the 

instrument to return to normal operating conditions before using it.

 

 

OPERATING INSTRUCTIONS

A. 

DIFFERENTIAL PRESSURE

  •  Press DIF ZERO button to start Differential Pressure test. 
  •  Press to DIF ZERO button stop Differential pressure test.

B. ZERO

I.  EM720 TEST SOURCES

C. HOLD 

 

•  Press HOLD BACKLIGHT button to hold pressure  

 

  reading on display.

 

•  Press to HOLD BACKLIGHT button again to return to  

 

  live readings on display.

D. BACKLIGHT 

 

•  Press HOLD BACKLIGHT button and hold to turn on  

 

  display back light.  

 

•  Press HOLD BACKLIGHT button and hold to turn off  

 

  display back light. 

NOTE: 

Backlight has a 60 second duration. 

E. RECORD/MAX/MIN/AVERAGE

 

•  Press REC/MAX/MIN button  to record the  

 

  Minimum pressure, the Maximum pressure, and  

 

  Average pressure

 

•  Press REC/MAX/MIN button again to view Maximum  

 

  value captured 

 

•  Press REC/MAX/MIN button again to view Minimum  

 

  value captured 

 

•  Press REC/MAX/MIN button again to view Timed  

 

  mean average calculated

 

•  Press and hold the REC MAX/MIN button to exit.

 

 

WARNING

Maximum over pressure for this meter is 10 psi

F. UNITS

 

•  To change the measuring unit

 

•  Press UNITS button to change the selected unit

 

•  PRESS UNITS button again to scroll to the desired unit

 

•  Once the measuring unit is selected, it will remain until  

 

  another unit is selected.

 

•  Unit options:

  •  When the battery indicator its low.

  •  Loosen the screws;captive screws are used to  

    insure screws do not get lost, (Phillips-head screws)

  •  Remove battery cover.

  •  Replaced the batteries (3) AA batteries

  •  Replace battery cover, tighten screws.

G.  PRESSURE TEST

 

•  Left Port: negative pressure port, applying pressure on  

 

  this port will display a negative pressure.

 

•  Right Port: positive pressure port: applying pressure on  

 

  this port will display a positive pressure.

 

•  Use either port to a single source, by venting the other  

 

  port into the atmosphere.

 

•  The manometer will continually provide a  

 

  pressure reading.

 

•  Connect hoses to both ports from source for  

 

  differential pressure mode.

 

•  Press DIF ZERO button to toggle Differential  

 

  Pressure on and off.

•  Press = DIF/Differential Pressure

•  Press = HOLD

•  Press and hold = Backlight

•  Press x 1 = REC 
•  Press x 2 = MAX 
•  Press x 3 = MIN 
•  Press x 4 = AVG 

- bar

- mbar

- psi

- inHg

- Pa/kPa

- ozin

2

- kgcm

2

- inH

2

- ftH

2

O

- cmH

2

O

- mmHg

PRESSURE CONVERSIONS

Multiply

By

To Get

In. of H

2

O

0.002490891

bar

In. of H

2

O

0.577886661

ozin

2

In. of H

2

O

0.036127441

psi

In. of H

2

O

0.073555975

InHg

In. of H

2

O

2.490890781

mbar

In. of H

2

O

1.868321732

mmHg

In. of H

2

O

249.0890781

Pa

In. of H

2

O

0.249089078

kPa

In. of H

2

O

0.002540709

kgcm

2

In. of H

2

O

0.083320297

ftH

2

O

In. of H

2

O

2.538217706

cmH

2

O

A

B

C

E

F

G

H

D

J.  BATTERY REPLACEMENT

A.  Positive Pressure Input
B.  Negative Pressure Input 
C.  Return Plenum
D.  Gas Value
E.  Pressure Switch
F. Inducer
G.  Evaporator Coil
H.  Supply Plenum  

A

B

NOTE:

 

Prior to use the Manometer must be zeroed. To do this, 

ensure the Manometer is in a non-pressurized area and no 

hoses are connected. The Manometer has a 10 second count 

down upon powering on.

Отзывы: