Battery Replacement

Always use a fresh replacement battery of the specified size and type. 
Immediately remove the old or weak battery from the meter and 
dispose of it in accordance with your local disposal regulations. Old or 
defective batteries can leak chemicals that corrode electronic circuits.

            

WARNING!

To avoid electric shock, be sure to turn off the meter’s power and  
disconnect thermocouples from any equipment before you remove  
or install batteries.

 

To install a new battery, follow these procedures:

    1.  Remove the screws from the battery compartment cover on the  
    back of the meter and lift the cover (Fig 1).

    2.  Remove and discard the old batteries. Always dispose of old  
    batteries promptly in a manner consistent with local disposal  
   regulations.

            

WARNING!

Under 

NO

 circumstance should you expose batteries to extreme heat 

or fire as they may explode and cause injury.

    3.  Place a fresh batteries in the compartment.

NOTE:

 

If you do not plan to use the meter for a month or more, 

remove the battery and store it in an area that won’t be damaged by 
a leaking battery.

    4.  Reattach the battery compartment cover to the meter and  
    reinstall the screws.

15

These guidelines will help you attain long and reliable service from 
your meter:

    1.  Calibrate your meter annually to ensure it meets original  
    performance specifications.

 
    2.  Keep your meter dry. If it gets wet, wipe it dry immediately. Liquids  
    damage electronic circuits.

 
    3.  Whenever practical, keep the meter away from dust and dirt, which  
    can cause premature wear.

  
    4.  Although your meter is built to withstand the rigors of daily use, it  
    can be damaged by severe impacts. Use reasonable caution when  
    using and storing the meter.

Cleaning and Decontamination

Periodically clean your meter’s case using a damp cloth. 

DO NOT

 use 

abrasives, cleaning solvents or strong detergents, as they may damage 
the finish or affect the reliability of the structural components.

Storing the Thermocouples

The thermocouples with wire spools can be stored in the back of the 
thermometer.

    1.  Wind the wire around the wire spool.

    2.  Thread the end of wire through a hole of the wire spool. 

    3.  Thread the end of wire through the other hole of the wire spool.

    4.  Insert the end of wire under the loop and pull the end of wire.

14

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание DT301

Страница 1: ...DT301 DT302 Digital Temperature Logger INSTRUCTION MANUAL www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...the proper thermocouple type you are using Be sure the thermocouple you use can withstand the temperature extreme it may be exposed to in your service task Properly maintain your thermometer and cali...

Страница 3: ...C F K Temperature units 11 Secondary Display Internal temperature of the thermometer MEMORY MIN MAX AVG and T1 or T2 DT302 reading Shows the memory location initially when a logged reading is recalled...

Страница 4: ...ss to accept the selected setup option 5 Buttons NOTE Press all the dual function buttons momentarily to activate the Upper Row Function and press these buttons for more than 1 second to activate the...

Страница 5: ...display shows and LOG 2 Press to display the logging interval choices 3 Press or until the display shows the logging interval you want and then press to select 7 Setting the Date 1 Entering Setup will...

Страница 6: ...erature being measured is outside the thermocouple s valid range 9 Type Color Type Color J Black T Blue K Yellow E Purple 4 If you selected a user defined logging interval 1 second to 23 hours and 59...

Страница 7: ...set of initial conditions when logging continuously It stores 9 999 sets of temperature readings and initial conditions when logging individual points manually 11 Holding the Displayed Temperature 1...

Страница 8: ...Starting and Stopping Logging Memory clear and PC communications are in accessible during logging Recall function is enabled during logging 1 Set the time and the logging interval see How to Change Se...

Страница 9: ...ery 4 Reattach the battery compartment cover to the meter and reinstall the screws 15 These guidelines will help you attain long and reliable service from your meter 1 Calibrate your meter annually to...

Страница 10: ...cified for ambient temperatures between 64 F 18 C and 82 F 28 C for a period of 1 year The above specifications do not include thermocouple error 16 Specifications Environmental General Thermocouple O...

Отзывы: