FEATURES

• Wireless Connectivity
• Visual LED alert
• Audible alert
• Backlight
• Auto power off

GENERAL SPECIFICATIONS

• Operating Temperature: 

32° to 104°F (0° to 40°C)

• Storage Temperature

: 14° to 122°F (-10° to 50°C)

• Operating Humidity

:  <80%

• Pollution Degree

:  2

• Over-range

: “OL” is displayed

• Dimensions: 

1.92 x 1.25 x 5.62” (49 x 32 x 143mm)

• Item Weight:  

0.35lb

• Calibration

:  Recommended Annually

• Certification

:  CE EMC & RED(STD EN 61326-1, EN 60950-1, EN 301 489-1), RoHS, FCC, KC

• Battery Type:  

(AAA) 3

• Range:

 1~999ppm

• Resolution: 

1ppm

• Accuracy: 

± 3% or ± 2ppm (whichever is greater)

•  App Compatibility:

  iOS

®

; 11.0 or newer and iPhone 5S or newer

Android™; 6.0 or newer

 NOTE: 

Requires compatible mobile device and FREE downloadable App “

COA2

”.

•  Bluetooth

®

 module:

 BGX13P22GA-V21R

•  FCC ID for Bluetooth

®

 module:

 QOQBGM13P

• 

RF Frequency Range: 

2400 MHz ~ 2483.5 Mhz

  RF Output Power (Max.):

 8 dbm

• Low battery indication
•  Max capture
•  Data Hold
•  Belt Clip
•  CO Sensor Self-Test

IMPORTANT SAFETY  WARNINGS

WARNING 

 

Read entire Safety Notes section regarding potential hazard and proper instructions before 

using this tester. In this manual the word “

WARNING

” is used to indicate conditions 

or actions that may pose physical hazards to the user. The word “

CAUTION

” is used to 

indicate conditions or actions that may damage this instrument. 

WARNING 

•  To ensure safe operation and service of the tester, follow these instructions. Failure to 

observe these warnings can result in severe injury or death.

•  This meter is designed for trade professionals who are familiar with the hazards of their 

trade. Observe all recommended safety procedures that include use of personal protective 

equipment.

•  Carbon monoxide is life threatening even at relatively low concentrations. Be sure you 

understand the risks before investigating potential leaks.

•  Do not use the tester if it appears damaged. 
•  Always adhere to national and local safety codes. 
•  This COA2 is specified to read Carbon Monoxide from 1-999ppm. The app may continue 

to read above this threshold. Professional safety precautions are recommended above 

35ppm.

•  Threshold safety levels are set to industry standards. By customizing these levels to 

higher CO ppm thresholds, users risk personal safety. These settings are saved and used 

after exiting and relaunching the App. To reset back to industry standards set the 

levels to: Green ≤ 

9

 ppm; Blue ≤ 

34

 ppm.

•  Any changes or modifications not expressly approved by the manufacturer could void the 

user’s authority to operate the equipment.

CAUTION 

•  The COA2 is designed for ambient testing only. DO NOT place the instrument in flue gas 

or warm air streams. 

•  The COA2 is not designed for in-flue detection. Readings more than 999 ppm will damage 

the sensor in the COA2, even if readings continue above the 999ppm range.

•  Ensure that the sensor vent at the top of the instrument is free from obstruction.

NOTE: 

A quick instrument check can be performed by the smoke from a blown out match. Let 

smoke enter the 

vent

. This will cause the indicated CO level to increase.

Содержание COA2

Страница 1: ...ipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equi...

Страница 2: ...can result in severe injury or death This meter is designed for trade professionals who are familiar with the hazards of their trade Observe all recommended safety procedures that include use of personal protective equipment Carbon monoxide is life threatening even at relatively low concentrations Be sure you understand the risks before investigating potential leaks Do not use the tester if it app...

Страница 3: ...n Press to view Maximum levels press again to return to live reading Press and hold to turn on back light press and hold again to turn off back light Back light turns off after 2 minutes E Hold Wireless BT Button Press to hold current readings press again to return to live reading Press and hold to connect wirelessly press and hold again to disconnect F Power Button Press to power on tester press ...

Страница 4: ...le 100 to 1000 Logging Interval Interval between the recorded adjacent samples Minutes 0 to 59 Seconds 1 to 59 C Info Press the INFO button to view information about the App including version Manual Press the Manual button to view the COA2 manual D UEi Apps Press the UEi Apps button to get to UEi master Apps E Logs Press the LOGS button to view a list of recorded samples Title Date Recording Inter...

Страница 5: ...d to be free from defects in materials and workmanship for a period of one year from the date of purchase If within the warranty period your instrument should become inoperative from such defects the unit will be repaired or replaced at UEi s option This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration tampering accident misuse ...

Отзывы: