Measuring Length of Wire

1. 

Turn the CLM100 on and perform the calibration procedure. 

2. 

Allow the CLM100 to attain the same temperature as the wire under test. 

 

NOTE: 

Temperature affects accuracy of readings. Please see accuracy specifications. For best results, allow the 

CLM100 to attain the same ambient temperature as the wire under test. 

 

 

WARNING! 

 

Make sure wire under test is not energized. Never apply voltage to inputs. 

3. 

Strip the insulation back on each end of the wire being tested. 

 

NOTE:

 

Make sure both ends of the wire under test are clean and the conductor is fully exposed. The insulation 

must be stripped away so the Kelvin clips can be connected across the diameter of the wire. Use the abrasive pad 

to clean the wire ends. 

4. 

Using the selector on the CLM100, turn to the size of wire under test. 

5. 

Press the 

“COPPER”

 button if copper wire is being tested.  

The 

“CU”

 enunciator will illuminate in the top left corner of the display. 

6. 

Press the 

“ALUM”

 button if aluminum wire is being tested.  

The 

“AL”

 enunciator will illuminate in the top left corner of the display. 

7. 

Press the 

“FT” 

button if you require readings to be in feet.  

The 

“ft”

 enunciator will illuminate in the display. 

8. 

Press the 

“M”

 button if you require readings to be in meters.  

The 

“m”

 enunciator will illuminate in the display. 

9. 

Connect a Kelvin clip to one end of the wire and the other  

Kelvin clip to the other end of the wire. 

10.  Read the length of wire directly from the display.  

Please note the 

“k”

 enunciator illuminates if measurements are at or above 1000 feet/meters. 

11.  Disconnect the test leads from the unit when not in use. 

Low Battery Indication

The 

“BAT”

 enunciator will illuminate in the lower left side of the display to indicate battery voltage is low.  

The battery should be changed immediately to ensure proper function and accuracy. Only alkaline 9 Volt  

batteries should be used.

Measuring Resistance

1. 

If the resistance to be measured is wire, follow steps 1 through 3 under “Measuring Length of Wire.” 

Then follow steps 2 and 3 below. If a discrete resistor is being measured, turn the cable length meter  

on and perform the calibration procedure.

2. 

Using the selector on the CLM100, turn to “R” on the dial.

3. 

Read the resistance of the wire directly from the display.

Содержание CLM100

Страница 1: ...CLM100 Cable Length Meter 1 800 547 5740 www ueitest com email info ueitest com INSTRUCTION MANUAL ENGLISH ...

Страница 2: ...8 8 8 8 Introduction Features icludes Safety Tips International Symbol Instructions Calibration Procedures Measuring Length of Wire Low Battery Indication Measuring Resistance Specifications Operational Hints Warranty Disposal Cleaning Storage ...

Страница 3: ...gs Please see accuracy specifications For best results allow the CLM100 to attain the same ambient temperature as the wire under test The length of time this will take depends on the ambient temperature Typically it will take 10 to 15 minutes for the CLM100 to attain equal ambient temperature INTRODUCTION Before using this meter read all safety information carefully In this manual the word WARNING...

Страница 4: ...ks and the red test leads into the other pair of input jacks Ignore the gray marking on the banana plug This is very important to ensure that the meter works correctly If black and red test leads are mixed the unit will give a false reading Fig 1 INSTRUCTIONS Fig 1 Fig 2 NOTE Make sure clips are as close together as possible Use the tips of the Kelvin clips when performing measurements on small di...

Страница 5: ...illuminate in the top left corner of the display 7 Press the FT button if you require readings to be in feet The ft enunciator will illuminate in the display 8 Press the M button if you require readings to be in meters The m enunciator will illuminate in the display 9 Connect a Kelvin clip to one end of the wire and the other Kelvin clip to the other end of the wire 10 Read the length of wire dire...

Страница 6: ... 3 LSD LSD least significant digit Resistance 0 to 65Ω 2 of reading Operating Temperature 32 to 104 F Operating Humidity 20 to 80 RH Storage Temperature 0 to 120 F Auto power off After 5 minutes approx Battery Life Depends on use Typically 40 hours Extended measurements times can lower battery life to no less than 6 hours WARNING This meter is NOT designed to measure less than 25ft cable SPECIFICA...

Страница 7: ...dequately from both ends of the wire under test This will enable measurements to be accurate Ensure that the alligator clips are connected across the diameter of the wire under test When measuring wire for insertion into conduit add extra wire to compensate for the accuracy of the meter For example 205 feet of wire is needed to run inside a piece of conduit that is 200 feet long This would allow 2...

Страница 8: ...xpenses or economic loss A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge Return the unit postage paid and insured to 1 800 547 5740 FAX 503 643 6322 www ueitest com Email info ueitest com This warranty gives you specific legal rights You may also h...

Отзывы: