GENERAL SPECIFICATIONS

 

IMPORTANT SAFETY  WARNINGS

  Read entire Safety Notes section regarding potential hazard and proper instructions before using this analyzer. In this manual the 

word “

WARNING

” is used to indicate conditions or actions that may pose physical hazards to the user. The word “

CAUTION

” is used to 

indicate conditions or actions that may damage this instrument. 

 

WARNING

To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe 

injury or death.

 

WARNING

 

• Do not use this analyzer during electrical storms or in wet weather.

• To avoid false readings, charge batteries if a low battery indicator appears.  

• Always adhere to national and local safety codes. Use proper personal protective equipment (PPE)  

 

WARNING

This analyzer extracts combustion gases that may be toxic in relatively low concentrations. These gases are exhausted from the back 

of the analyzer.

This analyzer must only be used in well-ventilated locations by trained and  competent persons after due consideration of all 

potential hazards. 

Users of portable gas detectors are recommended to conduct a “bump” check before relying on the unit to verify an atmosphere is free 

from hazard. A ‘bump” test is a means of verifying that an instrument is working within acceptable limits by briefly exposing to a known 

gas mixture formulated to change the output of all the sensors present.

NOTE: 

This is different from a calibration where the instrument is also exposed to a known gas mixture but is allowed to settle to a 

steady figure and the reading adjusted to the stated gas concentration of the gas of the test gas.

•  Operating Temperature:  

32° to 112°F (0° to 45°C)

•  Storage Temperature:  

0° to 120°F (-18° to 50°C)

•  Operating Humidity:  

10% to 90% R.H.

•  Back light: 

Yes

•  Dimensions: 

7.87 x 1.77 x 3.5 inch

•  Item Weight: 

1.35 lb

•  Calibration: 

Recommended Annually

•   Certification: 

CE Conformity, RoHS, REACH Compliant,  

 

   AHRI 1260 standard 

•  Battery Size: 

Alkaline or NiMH AA 3

•  Accuracy: 

± (% of r # of least significant digits)

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Содержание C165-N

Страница 1: ...C o m T e s t Prs Tem p Exch Test Room CO Combustion Analyzer C165 CO C O 2 T E M P P R S INSTRUCTION MANUAL ENGLISH C165 Residential Commercial Combustion Analyzer www calcert com sales calcert com...

Страница 2: ...ane Wireless Printer App Home Android Screen 16 Kane Wireless Printer App Android Settings Screen 16 Kane Wireless Printer App Android Personal Details Screen 16 Temperature Testing 17 Pressure Temper...

Страница 3: ...zer must only be used in well ventilated locations by trained and competent persons after due consideration of all potential hazards Users of portable gas detectors are recommended to conduct a bump c...

Страница 4: ...ctive Rubber Boot with Magnets O Serial Number QR Code Serial Number viewable under Protective Boot P Sensors Fitted label under Protective Boot Sensors that can be fitted in unit when shipped CO H2 C...

Страница 5: ...Analyzer C165 CO C O 2 T E M P P R S ANALYZER OVERVIEW CONT A Sensors Fitted CO NO CO H2 CO2 O2 Serial No UEiTEST INSTRUMENTS B C D E F G H I J M N T U W V X L K Q S R P O T2 T1 P2 P1 TOP BOTTOM Narro...

Страница 6: ...llation of boilers A low flow detection system warns of low flow and switches the pump off This also helps to prevent water ingress from overfilled water traps The analyzer has a protective rubber boo...

Страница 7: ...r O2 prior to shutting the unit off The meter will not switch off until the CO reading is below 20 ppm CAUTION The probe will be hot from flue gases Remove the probe from the flue and allow it to cool...

Страница 8: ...e flue Use the flue probes depth stop cone to set the position With balanced flues make sure the probe is positioned into the flue so no air can back flush into the probe CAUTION Ensure the flue probe...

Страница 9: ...o EXIT the MENU at any time simply move the rotary switch to any position other than Menu Any changes that have not been entered will be ignored MAIN MENU SUB MENU OPTIONS COMMENTS UNITS FUEL TYPE NAT...

Страница 10: ...an Menu Any changes that have not been entered will be ignored MAIN MENU SUB MENU OPTIONS COMMENTS REPORT AUX Stored AUX tests VIEW DEL ALL BACK COMBUSTION Stored combustion tests VIEW DEL ALL BACK CO...

Страница 11: ...ystem conditions are stable The rotary switch can be used to display the following information FLUE 1 Fuel type can be changed via MENU or STATUS setting Carbon Dioxide Oxygen left after combustion Sh...

Страница 12: ...option SCREEN Press Use and to navigate to the sub menu option AUX Press The display will show Press and a third line will appear Use and to navigate to the desired parameter to be displayed on line...

Страница 13: ...ER INTEGRITY TEST There are many methods to test heat exchange integrity One of these is to observe the Excess Air O2 and CO readings both before and after the blower turns on If the heat exchanger is...

Страница 14: ...Use or Arrow Buttons to select Printer Press button Use or Arrow Buttons to select Printer type Wireless KM IRP Kane IRP 2 Serial Wireless Printer App Please see pages 15 and 16 To charge Printer if o...

Страница 15: ...T screen Select EMAIL PRINTOUT A message window will open Enter email address Add message notes to Printout Send message Select CLEAR CONSOLE to delete a Printout Press to Confirm deletion To print Sa...

Страница 16: ...nect an analyzer Select disconnect from Printout screen Adding Notes Emailing from the Kane Wireless Printer App After a report is on the app Press the Pen icon on the top right of the app screen Pres...

Страница 17: ...low Temp Eg Return Temp Differential Temp Press to print a full pressure test or send to Smart Device via optional Wireless module Hold for 2 seconds to log a pressure report PRESSURE MEASUREMENT GOOD...

Страница 18: ...5 reading unspecified 0 3 volume 1 0 reading 1 0 reading 0 2 reading 5 reading Nitric Oxide Sensor optional 0 to 100ppm Overrange to 1500ppm 1ppm 2ppm 30ppm 1 5ppm 100ppm 1 5 reading 100ppm Pressure d...

Страница 19: ...017 IEC62321 7 1 2015 IEC62321 6 2015 AHRI 1260 ELECTROMAGNETIC COMPATIBILITY European Council Directive 89 336 EEC requires electronic equipment not to generate electromagnetic disturbances exceeding...

Страница 20: ...O2 CO2 CO Stack Temp Efficiency Hi Low fire Gas Pressure Supply and Return Water temp 80 Furnace Verify proper combustion O2 CO2 CO Stack Temp Vent Pressure Efficiency Verify Set Up Gas Pressure Test...

Страница 21: ...ssure Temperature Rise AC side Static Pressure Drop across coils WHAT RESULTS ARE GENERALLY ACCEPTABLE Atmospheric Gas Fixed Burners Gas Fired Burners Oil Fired burners 2 Oil Fuel Positive Overfire Ga...

Страница 22: ...vice of this instrument is to be performed by qualified personnel only Improper repair or service could result in physical degradation of the instrument This could alter the protection from personal i...

Страница 23: ...tment Take great care to ensure they are fitted with the correct battery polarity Replace the battery cover and the protective rubber boot Time and Date When changing the batteries the time and date w...

Страница 24: ...ak detectors Any accessories that are returned will be checked Packing Your Analyzer Put analyzer and probes back in their cases The case should be put into a box with 1 2 inches of packing on each si...

Страница 25: ...temperature and then reference a slide scale that would give you the relative efficiency number UEi s electronic combustion analyzers perform the measurements on a continuous basis and can calculate t...

Страница 26: ...e inoperative from such defects the unit will be repaired or replaced at UEi s option This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from a...

Отзывы: