background image

WARRANTY

The C161 combustion analyzer is warranted for one year including sensors. If within the warranty period 

your instrument should become inoperative from such defects, the unit will be repaired or replaced at 

UEi’s option. This warranty covers normal use and does not cover damage which occurs in shipment or 

failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper mainte-

nance (calibration). Batteries and consequential damage resulting from failed batteries are not covered 

by warranty. Any implied warranties, including but not limited to implied warranties of merchantability 

and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss 

of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or 

for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof 

of original purchase date will be required before warranty repairs will be rendered. Instruments out of 

warranty will be repaired (when repairable) for a service charge. Warranty only covers hardware and 

does not extend to software applications. Contact UEi for specific warranty and service information. 

UEi Test Instruments  •  1-800-547-5740  •  [email protected]

This warranty gives you specific legal rights. You may also have other rights which vary from state to state.

Download the full 

Owners Manual at 

UEiTEST.COM or 

SCAN THIS CODE

POST TESTING

BATTERIES

The analyzer is fitted with 3 

(AA) size rechargeable batter-

ies. Observe correct polarity 

when replacing.  

Always check operation 

immediately after battery 

replacement.

Do not leave batteries in unit for 

extended periods of non-use.

WARNING

Do not recharge with Alka-

line batteries fitted. Alkaline 

batteries are not rechargeable. 

Attempting to recharge alkaline 

batteries may result in product 

damage and create a fire risk.

Time and Date will need to be 
reset after changing batteries. 
Always dispose batteries using 

approved disposal methods that 

protect the environment.

Remove the probe from the flue 

and allow analyzer to purge with 

fresh air until readings return to 

zero. O2 to 20.9%, CO to Zero 

CAUTION:

  probe tip will be HOT.

POWERING OFF

When you power off the C161, there is a 10 second purge.

CAUTION

Make sure you do not exceed the analyzer’s operating specifications. 
•  Do not exceed the flue probes maximum temperature (1112˚F)
•  Do not exceed the analyzer’s internal temperature range 112°F (50°C)
•  Do not put the analyzer on a hot surface
•  Do not exceed the water trap’s level
•  Do not let the particle filter become dirty and blocked

Содержание C161

Страница 1: ...ZER BEFORE USING Register within 30 Days of Purchase to Get 10 Off Your First Year Calibration Keep up on the latest Accessories Upgrades and Videos Scan Now for Easy Online Registration or Visit www...

Страница 2: ...boot with built in magnets Log Print Temperature screen LED Water Trap Full Indication Water Trap Window K type temperature inputs Combustion hose input Water trap drain plug Power button Display line...

Страница 3: ...L U E 1 AUX FLUE 2 T E M P Combustion Analyzer C161 CO C O 2 T E M P MENU SCREEN C161 START UP STATUS SCREEN Rotate Selector Dial to STATUS to view parameters Selected Fuel Ti Ambient Temperature ATM...

Страница 4: ...M P Combustion Analyzer C161 CO C O 2 T E M P Flue 2 displays CO ppm Losses calculated Excess air Make any adjustments needed for proper Combustion and wait for analyzer to display change in readings...

Страница 5: ...lyzer C161 CO C O 2 T E M P STATUS F L U E 1 AUX FLUE 2 T E M P Combustion Analyzer C161 CO C O 2 T E M P STATUS F L U E 1 AUX FLUE 2 T E M P Combustion Analyzer C161 CO C O 2 T E M P AUX displays 5 l...

Страница 6: ...ombustion Analyzer C161 CO C O 2 T E M P To print the LOG Press and buttons until PRINT is selected between two arrow icons Press to select to start printing STATUS F L U E 1 AUX FLUE 2 T E M P Combus...

Страница 7: ...nd service information UEi Test Instruments 1 800 547 5740 info ueitest com This warranty gives you specific legal rights You may also have other rights which vary from state to state Download the ful...

Страница 8: ...12 Month warranty 2 Day turn around on all standard recertification services with pre approved payment Our recertification teams are factory certified and proud to provide industry leading turnaround...

Отзывы: