GENERAL

Misuse of this device May cause explosion and personal 

injury.  these instructions Must be thoroughly read and 

understood before device is installed.

this  device is suitable for use in class i, division 1, 

groups b, c and d; class ii, division 1, groups e, f and g; 

class iii; or non-hazardous locations only.  enclosure 

type 4x, 7 & 9.

The device has been certified in accordance with the 

applicable requirements of the following standards:

• 

iec 60079-0, 6

th

 edition, revision date 2013/12

• 

iec 60079-1, 7

th 

edition, revision date 2014/06

• 

iec 60079-31, 2

nd 

edition, issue date 2013/11

• 

en 60079-0:2012+a11:2013

• 

en 60079-1:2014

• 

en 60079-31:2014

this  device  is atex certified for equipMent category 2.  

suitable for appropriate use in gas zone 1 & dust zone 

21 applications.

 

deMKo 09 atex 0815573x 

 

0539 iecex ul 03.0001x

 

ii 2 g ex db iic t6 gb

 

ii 2 d ex tb iiic t85°c db ip66

 

-40°C ≤ Tamb. ≤ + 75°C

to prevent ignition of hazardous atMospheres, 

disconnect supply circuits before opening.  Keep cover 

tight while circuits are energized.

MaxiMuM teMperature* stated in literature and on naMe-

plate Must never be exceeded, even by surges in the 

systeM.  occasional operation of unit up to Max. teMper-

ature is acceptable (e.g., start-up, testing).  continuous 

operation should be restricted to the designated adjustable 

range.

*Maximum temperature - the highest temperature to which a sensing ele-

ment may be occasionally operated without adversely affecting set point 

calibration and repeatability.

this device does not have any field replaceable parts. 

any substitution of coMponents May iMpair suitability 

for class i, division 1.

the 120 series temperature switch utilizes either a liquid filled sensing stem 

(immersion stem, direct mounting) or liquid filled sensing bulb (bulb & capil-

lary, remote mounting) to detect a temperature change.  the response at 

a pre-determined set point(s), actuates a spdt, dual spdt, or dpdt snap-

acting micro switch(es), converting the temperature signal into an electrical 

signal.  control set point(s) may be varied by turning the adjustment hex 

(c120, f120) or the external knob(s) and pointer(s) (b121, b122, e121, 

e122,820e, 822e) according to the procedures outlined (see part ii - 

adjustments)
please refer to the product technical brocures for product specifications.  

product technical brochures may be found at www.ueonline.com.

ue declarations and third party issued certifications are available for 

download at www.ueonline.com/prod_approval.

date code format on nameplate is “yyww” for year and week.

TOOLS NEEDED

 – screwdriver/adjustable wrench to 1 1/2”

MOUNTING

to prevent electrostatic discharge, wipe down cover 

and enclosure of any dust build up before reMoving 

cover.

install device where shocK, vibration and 

teMperature fluctuations are MiniMal. do not Mount 

device in aMbient teMperatures that exceed the 

liMits on the naMeplate for the appropriate area

Mount device to prevent Moisture froM entering 

the enclosure. it is iMperative to use properly rated 

explosion-proof sealing fittings for electrical wire 

entry.
to prevent ignition of hazardous atMospheres, seal 

conduit runs within 18 inches of enclosure

types c120, f120, 820e and 822e are provided with two 

3/4” npt electrical conduit openings, either of which or 

both can be used during installation.  a 3/4” explosion 

proof plug* is provided for properly plugging the unused 

conduit opening.  the explosion proof plug Must be properly 

installed.

*plug is approved explosion-proof with the product as a full assembly and does not carry indi-
vidual markings.

do not KnocKout any plugs on explosion-proof types 820e 

or 822e

IMT120-12

120 Series 

Explosion-Proof Temperature and 

Indicating Temperature Switches 

and Controls

Local Mount Types B121, B122, C120

Remote Mount Types E121, E122, F120; 820E, 

822E 

Please read all instructional literature carefully and thoroughly before starting.  Refer to the final page for the listing of 
Recommended Practices, Liabilities and Warranties.  For functional safety applications, please refer to the safety manual which 
can be downloaded from www.ueonline.com.

U N I T E D   E L E C T R I C 
C O N T R O L S

Installation and Maintenance 

Instructions

Part I - Installation

SIL2

Certified

Содержание B121

Страница 1: ...signal Control set point s may be varied by turning the adjustment hex C120 F120 or the external knob s and pointer s B121 B122 E121 E122 820E 822E according to the procedures outlined See Part II Adjustments Please refer to the product technical brocures for product specifications Product technical brochures may be found at www ueonline com UE declarations and third party issued certifications ar...

Страница 2: ... wrench on the temperature housing hex when mounting the device do not tighten by turning the enclosure as this will damage sensor and weaken solder and welded joints vertical mounting temperature probe facing down is recommended however device can be mounted in any orientation with adherence to previous warnings and exceptions below Remote mount types E121 E122 F120 temperature devices may be mou...

Страница 3: ...r the switch to click Loosen adjustment A and move the Adjustment Pointer until it agrees with the Indicating Pointer see Figure 5 When the switch clicks re tighten the screw Type 822E NOTE Type 822E has a single knob and pointer for both switches Both switches are standardly factory set together within 5 of the dial range Turning the knob positions both switches simultaneously maintaining a const...

Страница 4: ...g screws Re position the housing index against the calibration on the instrument case or skeleton casting at a rate of 1 divi sion line per capillary length listed in Figure 6 Move to the left if capillary is to be added to the process or to the right if capillary is to be removed from process Added to or taken away from the process Model Number Range Cap Length Division 1 180 to 120 F 2 ft 2 125 ...

Страница 5: ... 1mm 4 11 16 119 3mm 1 11 16 43 2mm 2 1 4 57 5mm 1 17 32 38 9mm 3 8 9 5mm A 7 8 22 2mm BULB SET POINT ADJUSTMENT KNOB SET POINT INDICATING POINTER RED CLEARANCE FOR 1 4 SCREW 4 MT G HOLES TEMPERATURE INDICATING POINTER BLACK 3 4 NPT E C BOTH SIDES B LU B LK R E D V LT O R N Y E L S W T 1 S W T 2 N C C O M N O N C C O M N O 5 64 2mm SOCKET COVER LOCK SCREW GROUND SCREW 3 4 NPT E C PLUGGED ADJUSTMEN...

Страница 6: ...uld endanger property or personnel For all applications a factory set unit should be tested before use Electrical ratings stated in literature and on nameplate must not be exceeded Overload on a switch can cause damage even on the first cycle Wire unit according to local and national electrical codes using wire size recommended in installation sheet Do not mount unit in ambient temp exceeding publ...

Отзывы: