10
MENU 03 ADD LUBE AMOUNT.
The number of strokes of
the grease gun used to apply the grease can be added after
the lubricant has been applied and Add Lube Amount has been
selected.
To select this feature:
Enter set up mode and go to Menu 03
Click the Sensitivity dial to select and spin it to "ON”
Click the Sensitivity dial to set
To exit press and hold the Sensitivity dial
MENU 04 INSTRUMENT SET-UP.
The factory default is “MANUAL”. All adjustments are
made by the inspector while going throug
h the route. The “AUTOMATIC” setting is used after
the initial baseline data has been uploaded to the Ultraprobe 401. In the Automatic setting, the
instrument will move sequentially from one test point to the next, and set itself for the original
baseline setup, which will include the Frequency and Sensitivity for that point.
FOR EXAMPLE:
If the operator is testing bearings, the instrument will move from test point 1
to test point 2 and the if the baseline data was set at a sensitivity level of 43 with a frequency
of 30 kHz, the instrument will automatically set for these parameters.
To change this setting:
Enter set up mode and go to Menu 04
Click the Sensitivity dial to select. The selections are
“MANUAL” and “AUTO”
Spin to select, click to set
To exit, press and hold the Sensitivity dial