IPN Series
IPN1202HD-5241 Installation Guide
01A.03
UDP Technology Ltd.
11
Sensor Input (D/I)
The camera provides 1 channel D/I. It can be connected to either a voltage type sensor or
relay type sensor as the following figures. Settings can be done through the camera’s
configuration webpage.
Input voltage range: 0VDC minimum to 5VDC maximum, Max 50mA
Input voltage threshold: 1.5V
Caution
!
Do not exceed the maximum input voltage or relay rate.
Alarm (DO) connection
Only the relay type is supported.
Relay Rating: Max 24VAC 500mA or 12VDC 1A
+5V
DI
COM
DI
COM
+
-
Relay Type
Voltage Type
+
-
Output of
Sensor
Output of
Sensor
Internal
Internal
+
-
Mic
Amp Speaker
Out
In
AUDIO