LIMITED LIFETIME GUARANTEE

Residential R.O.

U

DI

 hereby guarantees to the original purchaser (only) that as long as he/she owns the following 

equipment  it  will  be  free  of  defects  in  material  and  workmanship  from  date  of  origi-nal 

installation. The exceptions to this guarantee are as follows:

*1.

Storage Tank - 60 Months

*2.

Faucet Assembly - 60 Months

*3.

Flow Control, O-rings, Tubing, Fittings and Shut Off Assembly - 36 Months

*4.

TFC Membrane - 36 Months, Prorated 4th-36th Months

*5.

Disposable Cartridges - No Guarantee

*Guarantee only for manufacturing defects

GENERAL CONDITIONS

Damage to any part of the Reverse Osmosis unit because of misuse, misapplication, neglect, 

alteration, accident, physical damage, fouling and/or scaling of membrane by dirt, sediment, 

minerals or bacterial attack, installation or operation, contrary to our printed instructions, or 

damage caused by freezing, flood, fire, or an Act of God are not covered by this guarantee. In all 

such cases, parts and service charges will apply. Parts returned to UDI should be sent with freight 

to and from factory, MRA plus handling charges, paid by customer.

We assume no guarantee liability in connection with this Reverse Osmosis unit other than as 

specified herein. (THIS GUARANTEE IS IN LIEU OF ALL OTHER GUARANTEES, 

EXPRESS 

OR IMPLIED, INCLUDING GUARANTEE OR FITNESS FOR A PARTICULAR 

PURPOSE.) We do not authorize any person or representative to assume for us any other 

obligations on the sale of this Reverse Osmosis unit.

Behind this product are years of research, design and production skills. Your Reverse Osmosis 

unit has been carefully tested and approved at our factory. Through this guarantee, we are dem-

onstration our confidence in UDI equipment.

FOR THIS GUARANTEE TO BE VALID, 

THE FOLLOWING CONDITIONS MUST BE MET:

Membrane 

TFC

Water 

Pressure 

40 

100 

PSI

Water 

Temperature 

40° 

100° 

F

pH 

2-11

TDS-Max 

1800PPM

Содержание Ultra 6

Страница 1: ...E MANUAL Under The Sink Reverse Osmosis Systems Ultra 6 KC5000 UDI 11225 St Johns Industrial Parkway N Jacksonville FL 32246 www UDIwater com 800 741 4426 Printed in the U S A Copyright 2014 2023 299244 Updated 10 10 2023 ...

Страница 2: ...ced Stage 3 and Stage 4 KDF GAC filter recommended change 12 months The third stage contains a KDF GAC filter KDF Kinetic Degradation Fluxion is a high purity copper zinc formulation which removes chlorine lead mercury iron and hydrogen sulfide from the water Removing these impurities prolongs the life of to Reverse Osmosis membrane The GAC filter Granular Activated Carbon has an extremely large a...

Страница 3: ...imum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 10 Grains Per Gallon Hardness Recommended hardness not to exceed 10 grains per gallon or 170 parts per million System will operate with hardness over 10 grains but the membrane life may be shortened Addition of a water softener may lengthen the membrane life Copper Tube Reverse Osmosis water should not...

Страница 4: ... QTY PART NO DESCRIPTION 1 1 KC5001 ULTRA 6 MANIFOLD 2 1 KC5002 SEDIMENT FILTER 5 MICRON 11 3 1 KC5003 CARBON BLOCK 5 MICRON 11 4 1 KC5004 KDF GAC CARBON FILTER 11 5 1 KC5005 TFC MEMBRANE 11 6 1 KC5006 POST CARBON GAC FILTER 11 7 1 70 3521 TANK SHUT OFF VALVE 3 8 X 1 4 8 1 70 6020 2 8 GALLON WHITE STEEL TANK 9 1 70 5542 703 SERIES BRUSHED NICKLE FAUCET 10 1 09 9160 ANGLE STOP ADAPTER 11 1 09 0515 ...

Страница 5: ...ing UDI accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for drilling a hole in a marble counter top Drill a Hole for the Reverse Osmosis Faucet How to use the Quick Connect Fittings To make a connection the tube is simply pushed into the fitting The unique locking system hol...

Страница 6: ...faucet adapter fitting Thread it on to the faucet stem be careful not to overtighten as it may crack the fitting Please see Fig 1 and Fig 2 Fig 1 Fig 2 5 Non Air Gap Faucet 4 In the parts bag locate the blue 1 4 tube Connect one open end of the blue tube to the RO faucet 1 4 quick connect fitting making sure the tube is pushed in all the way to the tube stop FAUCET TANK IN DRAIN 5 Connect the othe...

Страница 7: ...t the cold water supply line from the angle stop water valve and install the Angle Stop Adapter as pictured Angle Stop Adapter 09 9160 Connect Male Threaded end to Cold Water Supply Line Connect Female Threaded end to Cold Water Angle Stop Valve A B To Kitchen Faucet Cold Water Angle Stop Valve Angle Stop Adapter Cold Water Supply Line A B 5 Insert the open end of the orange 1 4 tube into the open...

Страница 8: ...f a second sink drain is available install it above the cross bar on the second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug Caution P Trap Elbow 4 Assemble the drain saddle around the drain pipe and align drain saddle fitting opening with the hole drilled in the previous step you may use a small screwdriver to feed through the drain saddle into t...

Страница 9: ...e to be mounted to allow for future system maintenance Using the mounting holes on the bracket mark the location for the mounting screws on the cabinet wall under the sink In the parts bag locate the two self tapping screws Using an electric drill with a Phillips bit screw them into the cabinet at the marked location Hang the module on the screws using the mounting holes in the bracket 6 Connect t...

Страница 10: ...ld take 2 3 hours to complete 7 After the second tank is filled repeat 6 Then enjoy your filtered water 8 Check leaks daily for first week and periodically thereafter 9 You may notice that the water may be milky colored during the first week It is the air bubbles in the water It is normal and safe NOTE 1 Do not use with water that is microbiologically unsafe or of unknown quality without adequate ...

Страница 11: ...e is recommended CHECK AIR PRESSURE IN STORAGE TANK Important Check air pressure only when tank is empty of water 1 Turn off the incoming water supply to the RO 2 Open the RO Faucet and allow water to drain from the tank until it is completely empty Check air pressure in the storage tank when you notice a decrease in available water from the RO system Air can be added with a bicycle pump using the...

Страница 12: ...upply at the angle stop adapter The RO faucet must be off when filters are replaced To make the removal of the filter cartridges easier the heads cartridges may be swiveled up to 90 degrees Step 2 To install a filter cartridge Remove the seal cap and insert the cartridge into the valved head with the label facing to the left 9 o clock position rotating it clockwise 1 4 turn Step 3 To remove a filt...

Страница 13: ...it open until water begins to trickle out it will come out slowly Step 5 Turn on water supply to the system at the angle stop adapter Check frequently over the next 24 hours to ensure no leaks are present Step 4 Step 3 Note Step 2 Close the RO faucet allowing the storage tank to fill with water It may take 2 to 3 hours to fill the tank completely depending on the production capability of the membr...

Страница 14: ... production rate Add pressure to storage tank The pressure should be 8 10 psi when the tank is empty Slow production Low water pressure Crimps in tubing Clogged pre filters Fouled membrane Add a booster pump Make sure tubing is straight Replace pre filters Replace membrane Water taste or smell offensive Post carbon is depleted Fouled membrane Sanitizer not flushed out Replace post carbon Replace m...

Страница 15: ...l water sources treated and tested on regular basis to insure bacteriological safe quality DO NOT use with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts 2 Operating Temperature Maximum 100 F 40 5 C Minimum 40 4 4 3 Operating W...

Страница 16: ...ructions or damage caused by freezing flood fire or an Act of God are not covered by this guarantee In all such cases parts and service charges will apply Parts returned to UDI should be sent with freight to and from factory MRA plus handling charges paid by customer We assume no guarantee liability in connection with this Reverse Osmosis unit other than as specified herein THIS GUARANTEE IS IN LI...

Отзывы: