1. Installation instructions 

 

IMPORTANT INSTALLATION INSTRUCTIONS 

WARNING: 

The following instructions contain important safety information – To reduce the risk of severe injury : 

 

• 

READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 

• 

Keep these instructions to consult them after installation if necessary. 

• 

Unsuitable  application or wrong installation may result in a loss of system operating functions and consequently in damages 
or/and injuries. 

• 

The actuator is designed for applications on top hinged windows, roof windows, skylights and bottom hinged windows. 

• 

The actuator is intended for indoor use only. 

• 

Only original parts and  fittings shall be used to install the actuator. 

• 

The actuator shall be installed by qualified service person . 

• 

Prior to installation make sure that: 
- the actuator performances comply with the estimated application 
- window profiles and fittings are suitable to the stresses caused by the actuator 
- the minimum height of the window is higher than 32” (

800 mm) (for 15” stroke) 

- window fittings (hinges) and absence of obstacles allow complete opening 
- bottom hinged windows are provided with side checks 
- the existing electric systems comply with the regulations in force 
- power supply features are those indicated in the actuator specifications 

• 

The screws supplied are suitable for mounting the actuator on aluminium windows. 

• 

Do not wire this system with power applied. Connect power only after the connections are verified. Damage or incorrect 
operation may occur if connections are made with power applied. 

• 

Before connecting the actuator to power supply make sure it has been turned off to avoid electrocution. 

• 

Remote controls should be installed so as to keep in sight the system, at a minimum height of 5 feet (

1.5 m), so small 

children are not able to reach it. 

• 

We recommend to install, where possible, the actuator 8 feet (

 2,4 m) or more above the floor. 

• 

In case the window is accessible, we advise to provide the system with a switch off device to  be reached easily. 

• 

In case the actuator is installed on a mobile wing, make sure the supply cable is not subject to stress or squashing when 
operating.  

• 

When assembling and disassembling the actuator, take proper precautions to avoid accidental closing of the window  which 
might cause injuries to people (impact-squashing-cutting-shearing). 

• 

Do not install two actuators on the same window. 

• 

When connecting the actuator to accessories, read the installation instructions supplied with each item before beginning 
installation. 

• 

By feeding the actuator make sure that operation is regular and that opening and closing limit switches operate correctly. 

• 

Check for correct operation of the limit microswitches and make any necessary adjustment by acting on the tie-rod (7). 

• 

Do not carry out any work on the actuator (e.g. do not remove any part); in case of malfunctioning, contact only specialized 
personnel. 

 

1.1 Installation on

 

skylights (or top hinged with windowsill) 

• 

Draw the center line of the window and drill the holes (see Fig. A).

 

• 

Install the actuator following Fig. A and check for the closure of the window acting on the tie-rod (7).

 

• 

Use plugs to cover the holes 

 

1.2 Installation on top and bottom hinged windows (without windowsill); brackets part n° 37021U or n° 37493H to be 
ordered separately 

• 

Draw the center line of the window and drill the holes (see Fig.B-C-D).

 

• 

Install the actuator following Fig. B-C-D and check for closure of the window acting on the tie-rod (7).

 

 
1.3 Electric Connection 

• 

Make the electric connection following the wiring diagram (the colors identify the wires) 

• 

The standard wires recommended (in relation with the distance from the transformer to the farest actuator) are showed in the 
table of  the electric connection diagram. 

• 

Control cables section: 22 AWG. 

 

Warning: 

• 

Damages to the supply cable may result in a loss of system operating functions 

• 

Feeder and Voltage Supply Line must be in Class II 

 

Содержание TWIN MASTER 24V

Страница 1: ...OTICES MANUEL D UTILISATION INSTRUCTIONS ET INDICATIONS TOP HINGED WINDOWS FENETRES PROJECTANTES WITH WINDOW SILL WITHOUT WINDOWS SILL AVEC APPUI FENETRE A FLEUR BOTTOM HINGED WINDOWS ROOF WINDOWS AND...

Страница 2: ...e the actuator 8 feet 2 4 m or more above the floor In case the window is accessible we advise to provide the system with a switch off device to be reached easily In case the actuator is installed on...

Страница 3: ...move the split pin see fig A B item 5 do not carry out any intervention on the actuator do not remove or disassemble parts of the actuator in case of malfunction contact a qualified service person onl...

Страница 4: ...s dommages ou une op ration incorrecte peuvent avoir lieu si les connections sont r alis es alors que l actionneur est sous tension Avant de connecter l actionneur son alimentation lectrique assurez v...

Страница 5: ...cun liquide ne peut p n trer dans l actionneur Proc dez un test de l actionneur une fois par mois v rifiez les dommages de visu ainsi que le c ble d alimentation lectrique Afin d ouvrir la fen tre lor...

Страница 6: ...ILL INSTALLATION SUR FENETRES AVEC APPUI Item PART LIST LISTE DES PI CES Q ty 1 Actuator V rin 1 2 Screw for window sill Vis 4 3 Plug Bouchons 2 4 Screw for connector Vis pour connecteur 4 5 Split pin...

Страница 7: ...ON ON THE FRAME use bracket Part n 37021U to be ordered separately INSTALLATION SUR FENETRES A FLEUR utiliser le kit code 37021U optionnel Item PART LIST LISTE DES PI CES Q ty 8 Dovetail bracket Etrie...

Страница 8: ...ires cable Le v rin est fourni avec 1 5 m de cable 2 conducteurs Total distance from trafo to window Longueur totale de la ligne Wire size class II Section du cable Classe II 50 ft 15 m 20 AWG 100 ft...

Отзывы: