background image

PAGE 6

3330 Earhart Drive, Suite 208  

|

  Carrollton, TX 75006  

|

  Office: 972.556.0916  

|

  Fax: 972.910.8384

This product conforms with health, safety, and environmental protection standards for products sold within 
the European Economic Area (EEA). This product was tested by an ISO 17025 accredited laboratory and 

complies with the following CE directives and standards listed below:

 

  DIRECTIVES:

 Electromagnetic Compatibilities (2014/30/EU)

 

  STANDARDS: EMC: EN 61326-1:2013 Industrial; 

 

  Safety: EN/IEC61010- 1:2010+A1:2016

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) 

this device may not cause harmful interference, and 

(2)

 this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inter-
ference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, 
and if not installed and used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of 

the following measures: 

• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

• 

Consult the dealer or an experienced radio/TV technician for help

.

CERTIFICATIONS

OPM1

Contact us with any questions pertaining to this or any other SWIFT product.

uclswiftna.com

Office: 972.556.0916
Fax: 972.910.8384

CONTACT

Содержание TEK-4

Страница 1: ...uclswiftna com SECTION ONE LSSM LASER LIGHT SOURCE QUICK START GUIDE SECTION TWO LSSM LASER LIGHT SOURCE TECHNICAL GUIDE SECTION THREE OPM1 OPTICAL POWER METER QUICK START GUIDE SECTION FOUR OPM1 OPTI...

Страница 2: ...SECTION ONE LSSM LASER LIGHT SOURCE QUICK START GUIDE NORTH AMERICA...

Страница 3: ...SWIFT This unit offers 1310nm and 1550nm wavelengths When the LSSM is turned on the red light indicates which wavelength is selected The red light blinks to indicate when the 2kHz modulation is turne...

Страница 4: ...ts either the 1310nm or 1550nm wavelength on singlemode fiber It is important to use a test jumper to mate the LSSM to the fiber under test TRANSMITTING LIGHT Test Jumper Signal Propagates Down Fiber...

Страница 5: ...inserted they can cause damage to the LSSM output port and the unit may need to be repaired OUTPUT PORT MAINTENANCE LSSM When the LSSM s 2kHz modulation is active the selected wavelength indicator wi...

Страница 6: ...The LSSM provides over 1000 operations under normal conditions When the LOW BAT LED indicator is illuminated on the device the CR2 battery should be replaced or recharged depending on the battery type...

Страница 7: ...long term 15 min warm up 5nm 5nm SC FC ST LC interchangeable 2kHz Push button toggle auto off CR2 10 to 50 C 30 to 60 C 6 1 x 0 94 x 0 75 15 5 x 2 83 x 1 9cm 3oz 85 4g 3330 Earhart Drive Suite 208 Car...

Страница 8: ...FCC Rules These limits are designed to provide reasonable protection against harmful inter ference in a residential installation This equipment generates uses and can radiate radio frequency energy a...

Страница 9: ...SECTION TWO LSSM LASER LIGHT SOURCE TECHNICAL GUIDE NORTH AMERICA...

Страница 10: ...our FI2K Easy removal of the included SC adapter allows the light source ferrule to be cleaned preventing contamination of test jumpers Additional adapters are available This device maintains full co...

Страница 11: ...21 CFR 1040 11 Push button toggle auto off CR2 10 to 50 C 30 to 60 C 6 1 x 0 94 x 0 75 15 5 x 2 83 x 1 9cm 3oz 85 4g Interchangable Adapter SC shown Low Battery Indicator Modulation Control 2kHz CW Wa...

Страница 12: ...SECTION THREE OPM1 OPTICAL POWER METER QUICK START GUIDE NORTH AMERICA...

Страница 13: ...ed to internal storage The display flashes the indexed location where the reading has been saved Toggles through the saved readings on the device The indexed location wavelength and reading will flash...

Страница 14: ...ill briefly appear on screen every 8 seconds Press the button to toggle between dB and dBm modes Hold the button down when in dBm mode to set a reference on the OPM1 Press the button once to turn the...

Страница 15: ...S Press and hold the Save and Wavelength buttons simultaneously to delete all saved readings in the OPM1 s internal memory The screen flashes 0000 to indicate that the memory is empty NON VOLATILE MEM...

Страница 16: ...ckaging is damaged or otherwise unsatisfactory LOW BATTERY The OPM1 provides over 1000 operations under normal conditions When the BATT indicator is shown on the device screen the CR2 battery should b...

Страница 17: ...ailable LCD 2kHz 4000 measurements Mini USB live readings or data dump Push button toggle auto off 10 to 55 C 30 to 70 C CR2 6 1 x 0 94 x 0 75 15 5 x 2 83 x 1 9cm 3oz 85 4g 3330 Earhart Drive Suite 20...

Страница 18: ...FCC Rules These limits are designed to provide reasonable protection against harmful inter ference in a residential installation This equipment generates uses and can radiate radio frequency energy a...

Страница 19: ...SECTION FOUR OPM1 OPTICAL POWER METER REFERENCE TEST GUIDE NORTH AMERICA...

Страница 20: ...ch must be taken with OPM1 optical power meter to perform insertion loss testing on a variety of fiber types and setups INTRODUCTION EXAMPLE 1 Singlemode Fiber Point to Point 1 Jumper Page 2 EXAMPLE 2...

Страница 21: ...v ada The fiber under test is singlemode with LC connectors on each end The fiber under test may be up to 250 kilometers long In this example the fiber under test is 400 meters long TEST JUMPER The te...

Страница 22: ...d of the OPM1 Between 5 00 and 7 00dBm Page 4 The connectors on the Test Jumper should be cleaned to appropriate standards Use an inspection scope to verify fiber cleanliness Plug the connectors on th...

Страница 23: ...e with LC connectors on each end This method allows testing of connectors inside bulkheads One or both ends of this fiber under test may be inside bulkheads The fiber under test may be up to 250 kilom...

Страница 24: ...tween 5 00 and 7 00dBm Page 4 The connectors on the Test Jumper should be cleaned to appropriate standards Use an inspection scope to verify fiber cleanliness Plug the connectors on the Test Jumper in...

Страница 25: ...nectors on each end The fiber under test may be up to 250 kilometers long In this example the fiber under test is 400 meters long TEST JUMPER The test jumper is paired for loopback testing One end has...

Страница 26: ...ll display 0 00dB with some minor variation DO NOT switch the RP 460 back to the dBm mode The Test Jumper MUST remain attached to the DLS 355 Do not remove the Test Jumper from the optical link The co...

Страница 27: ...h end In this example the fiber under test is 400 meters long TEST JUMPER The test jumper is a one meter multimode fiber with SC and LC connectors The SC connector will be plugged into the LSMM LED so...

Страница 28: ...er on the OPM1 The Insertion Loss of the fiber under test will be shown on the OPM1 screen LOSS TEST The connectors on the Test Jumper should be cleaned to appropriate standards Use an inspection scop...

Страница 29: ...xample the fiber under test is 400 meters long TEST JUMPER The test jumper is paired for loopback testing One end has an SC connector and an LC connector and the other end has two LC connectors clippe...

Страница 30: ...cleaned to appropriate standards Use an inspection scope to verify fiber cleanliness Plug the clipped LC end of the Test Jumper into one end of the Fiber Under Test using the bulkhead as shown Plug th...

Отзывы: