18
5. Adjustment of hold plate section
1.
Position check of sensor mounting plate
If the hold plate section (1) and the press-down plate (2) are not properly positioned, the tape
will not be held firmly, and, the deposition section will deviate or the tape will get out of place
when tightening it.
1. Remove the rear table.
2. Cut the film tape about 10 to 20 cm and insert it between the tape press-down plate (1) and the
hold plate.
10 – 20cm
Tape
3. Press the INCHING switch to move the main spindle to the position where the tape press-down
plate (1) touches the hold plate and the guide is fully opened. (Position where the heater is not
raised.) The tape is interposed between the hold plate and the tape press-down plate (1).