![UC Living Rosmore Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/uc-living/rosmore/rosmore_owners-manual_3158719015.webp)
LT---- Iss - (--/--)
15
TENSIONING NUT
CLAMP SCREW
UC Living Rosmore Installation Instructions
SECTION NINE To Install the Appliance Continued
Fix the fire casing back into the
opening using the cable fixing
system as shown in do not cut
off loose ends of cable after
fixing, coil and tuck carefully
behind burner tray.
Note: when using the cable
fixing kit with the spacer, fix
and seal the spacer to the rear
of the appliance flange with the
screws and foam seal
provided.
CHECKING GAS SOUNDNESS
After completing the gas connection to the appliance, check for gas soundness in accordance
with current codes of practice.
FUEL BED LAYOUT
Important: -
Refer to the ‘Health & Safety Notice located on page 3 of this
booklet
before cleaning or replacing any refractory material.
Lay fuel bed as shown in the Users Section of these instructions.
ENSURE THE FUEL BED IS PLACED AS INDICATED IN THESE INSTRUCTIONS.
CHECKING OPERATION OF FIRE
Remove the screw from the pressure test point on the inlet elbow and fit pressure gauge. Turn
on gas the appliance. Purge the air from the appliance by rotating the control to the ignition
position, push in to allow the air in the pipework to be purged and the piezo to ignite the pilot.
Check that the electrode is sparking at the gap between the thermocouple tip and the electrode,
continue until pilot ignition is established. Depress the control knob slightly and rotate anti-
clockwise until the index symbol is aligned with the”
.”on the indicator label, release and allow
the appliance to run for a period of approximately 5 minutes. Check the inlet pressure is 20 + 1
mbar for Natural Gas (G20) or 37+ 1mbar for Propane Gas (G31).
CHECKING PRODUCT CLEARANCE
Check for satisfactory clearance of combustion products. Close all doors and windows and
leave fire burning for 5 minutes. Then position a smoke match just into the top of the fire
opening and move it left and right, all the smoke must be drawn into the flue. If spillage occurs,
allow a further 5 minutes. Should spillage still occur, remove the restrictor insert plate if still
fitted and repeat spillage test. If spillage still occurs turn off the fire and seek expert advice to
investigate the chimney/flue problem.