2.6.2
USB interface
☞
The USB interface is available for diagnostic purpose only.
2.6.2.1
Guidelines for USB circuit design
A suitable application circuit can be similar to the one illustrated in
, where direct external
access is provided for diagnostic purpose by means of test points made available on the application
board for
VUSB_DET
,
USB_D+
and
USB_D-
lines.
USB pull-up or pull-down resistors and external series resistors on
USB_D+
and
USB_D-
lines as
required by the USB 2.0 specification
are part of the module USB pins driver and do not need to be
externally provided.
SARA-R5 series
29
USB_D+
GND
TestPoint
17
VUSB_DET
TestPoint
28
USB_D-
TestPoint
Figure 66: SARA-R5 series modules USB application circuit providing access for diagnostic purpose
☞
It is highly recommended to provide accessible test points directly connected to the USB interface
pins (
VUSB_DET
,
USB_D+
,
USB_D-
) for diagnostic purpose.
☞
The USB interface pins ESD sensitivity rating is 1 kV (HBM according to JESD22-A114F). Higher
protection level could be required if the lines are externally accessible and it can be achieved by
mounting a very low capacitance (i.e. less or equal to 1 pF) ESD protection (e.g. the Littelfuse
PESD0402-140 ESD protection) on the lines connected to these pins, close to accessible points.
2.6.2.2
Guidelines for USB layout design
USB_D+
/
USB_D-
lines should be designed with differential characteristic impedance (Z
0
) as close as
possible to 90
and with common mode characteristic impedance (Z
CM
) as close as possible to 30
as defined by the USB 2.0 specification
, routed as differential pair, with length as short as possible,
avoiding any stubs, and avoiding abrupt change of layout.
However, the USB interface is available for diagnostic purpose only, and therefore the layout is not
very critical:
USB_D+
/
USB_D-
lines have to be routed as differential pair, with short length, up to the
related test points as illustrated in
2.6.3
SPI interfaces
☞
The SPI interfaces are not supported by the
“00” product version
of SARA-R5 series modules,
except for diagnostic purpose.
☞
Accessible test points directly connected to the
SDIO_D0
,
SDIO_D1
,
SDIO_D2
and
SDIO_D3
pins
may be provided for diagnostic purpose, alternatively to the highly recommended test points on
the USB interface pins.