SARA-R42 - Application note
UBX-20050829 - R02
MNO profiles
Page 19 of 58
C1-Public
shows an example of automatic MNO profile detection setting usage.
Command
Response
Description
AT+UMNOPROF=1
OK
Set the automatic MNO profile detection, the
automatic reset and enable the related URC.
AT+CFUN=15
DTE is required to perform first reboot
AT+UMNOPROF?
+UMNOPROF: 1,0
OK
UMNOPROF is ready to perform automatic selection,
another reboot is required.
AT+CFUN=15
DTE performs the second reboot
AT+UMNOPROF?
+UMNOPROF: 1,2
OK
Read the detected profile
Table 8: Setting automatic MNO profile detection example