TOBY-L1 and MPCI-L1 series - System Integration Manual
UBX-13001482 - R04
Advance Information
System description
Page 20 of 90
1.5.1.4
VCC and 3.3Vaux current consumption in fixed active-mode (power saving disabled)
When power saving is disabled, the module does not automatically enter the low power idle-mode whenever
possible: the module remains in active-mode. Power saving configuration is by default disabled. It can also be
disabled using the AT+UPSV command (refer to
TOBY-L1 series AT Commands Manual
[3] for detail usage).
The module processor core is activated during idle-mode, and the 26 MHz reference clock frequency is used. It
would draw more current during the paging period than that in the power saving mode.
Figure 6 illustrates a typical example of the module current consumption profile when power saving is disabled.
In such case, the module is registered with the network and while active-mode is maintained, the receiver is
periodically activated to monitor the paging channel for paging block reception.
ACTIVE MODE
0.32-2.56 s
Paging period
Time [s]
Current [mA]
0
Time [ms]
Current [mA]
0
RX
Enabled
200
100
300
200
100
300
Figure 6: An example VCC / 3.3Vaux current consumption profile versus time with power saving disabled and module registered
with the network: active-mode is always held and the receiver is periodically activated to monitor the paging channel