LISA-U2 series - System Integration Manual
UBX-13001118 - R19
Early Production Information
System description
Page 39 of 175
Figure 18 shows the modules power-on sequence from the power-off mode, describing the following phases:
The external supply is still applied to the
VCC
inputs as it is assumed that the module has been previously
switched off by means of the AT+CPWROFF command: the
V_BCKP
output is internally enabled as proper
VCC is present, the
RESET_N
of LISA-U2 series is set to high logic level due to internal pull-up to
V_BCKP
,
the
PWR_ON
is set to high logic level due to external pull-up connected to
V_BCKP
or
VCC
.
The
PWR_ON
input pin is set low for a valid time period, representing the start-up event.
All the generic digital pins of the modules are tri-stated until the switch-on of their supply source (
V_INT
):
any external signal connected to the generic digital pins must be tri-stated or set low at least until the
activation of the
V_INT
supply output to avoid latch-up of circuits and allow a proper boot of the module.
The
V_INT
generic digital interfaces supply output is enabled by the integrated power management unit.
The internal reset signal is held low by the integrated power management unit: the baseband processor core
and all the digital pins of the modules are held in reset state, which is reported for each pin of the module in
the pin description table of
LISA-U2 series Data Sheet
When the internal reset signal is released by the integrated power management unit, the processor core
starts to configure the digital pins of the modules to each default operational state.
The duration of these pins’ configuration phase differs within generic digital interfaces (3 s typical) and USB
interface due to specific host / device enumeration timings (5 s typical, see the section 1.9.3.1). The host
application processor should not send any AT command over the AT interfaces (USB, UART) of the modules
until the end of these interfaces’ configuration phase to allow a proper boot of the module.
After the interfaces’ configuration phase, the application can start sending AT commands, and the following
starting procedure is suggested to check the effective completion of the module internal boot sequence:
send AT and wait for the response with a 30 s timeout, iterate it 4 times without resetting or removing the
VCC
supply of the module, and then run the application.
VCC
V_BCKP
PWR_ON
V_INT
Internal Reset
System State
BB Pads State
Internal Reset
→
Operational Operational
Tristate / Floating Internal Reset
OFF
ON
Start-up
event
0 ms
~35 ms
~3 s
PWR_ON
can be set high
Start of interface
configuration
Generic digital interfaces
are configured
Figure 18: LISA-U2 series power-on sequence description
The Internal Reset signal is not available on a module pin, but the application can monitor the
V_INT
pin
to sense the start of the power-on sequence.
Any external signal connected to the UART interface, SPI/IPC interface, I
2
S interfaces and GPIOs must be
tri-stated when the module is in power-down mode, when the external reset is forced low and during the
module power-on sequence (at least for 3 s after the start-up event), to avoid latch-up of circuits and let a
proper boot of the module. If the external signals connected to the cellular module cannot be tri-stated,
insert a multi channel digital switch (e.g. Texas Instruments SN74CB3Q16244, TS5A3159, or TS5A63157)
between the two-circuit connections and set to high impedance during module power down mode, when
external reset is forced low and during power on sequence.