background image

EVK-M8T - User Guide  

UBX-14041540 - R05 

Troubleshooting

  

Page 18 of 22 

Early Production Information 

 

 

11

 

Troubleshooting 

My application (e.g. u-center) does not receive anything 

Check whether the blue LED on the evaluation unit is blinking. Also make sure that the USB cable is 
properly connected to the evaluation unit and the PC. By default, the evaluation unit outputs NMEA 
protocol on Serial Port 1 at 9600 Bd, or on the USB.  

My application (e.g. u-center) does not receive all messages 

When using UART, make sure the baud  rate is sufficient. If the baud  rate is insufficient, GNSS 
receivers based on  u-blox M8 GNSS  technology

 

will skip excessive messages. Some

 

serial port 

cards/adapters (i.e. USB to RS232 converter) frequently generate errors. If a communication error 
occurs while u-center receives a message, the message will be discarded. 

My application (e.g. u-center) loses the connection to the GNSS receiver 

u-blox M8 positioning  technology and u-center  both  have an autobauding feature. If frequent 
communication errors occur (e.g. due to problems with the serial port), the connection may be lost. 
This happens because u-center and the GNSS receiver both autonomously try to adjust the baud rate. 
Do not enable the u-center autobauding if the GNSS receiver has the autobauding flag enabled. 

The COM port does not send any messages 

Be sure that the slide switch at the front panel is set to I2C and not SPI. In SPI Mode the RS232 pins 
on the DB9 connector are switched off and the RxD and TxD output at the front panel are used for SPI 
(MISO, MOSI). 

 

NOTE: After changing the slide switch, always reset the EVK; if not, the change will not take place.   

Some COM ports are not shown in the port list of my application (e.g. u-center)  

Only the COM ports that are available on your computer will show up in the COM port drop down list. 
If a COM Port is gray, another application running on this computer is using it. 

The position is off by a few dozen meters 

u-blox M8  GNSS  technology starts up with the WGS84 standard GNSS  datum. If your application 
expects a different datum, you’ll most likely find the positions to be off by a few dozen meters. Don’t 
forget to check the calibration of u-center map files.  

The position is off by hundreds of meters 

Position drift may also occur when almanac navigation is enabled. The satellite orbit information 
retrieved from an almanac is much less accurate than the information retrieved from the ephemeris. 
With an almanac only solution, the position will only have an accuracy of a few kilometers but it may 
start  up faster or still navigate in areas with obscured visibility when the ephemeris from one or 
several satellites have not yet been received. The almanac information is NOT used for calculating a 
position, if valid ephemeris information is present, regardless of the setting of this flag. 

In NMEA protocol, position solutions with high deviation (e.g. due to enabling almanac navigation) can 
be filtered with the

 

Position Accuracy Mask. UBX protocol does not directly support this since it 

provides a position accuracy estimation, which allows the user to filter the position according to his 
requirements. However, the ‘Position within Limits’ flag of the UBX-NAV-STATUS message indicates 
whether the configured thresholds (i.e. P Accuracy Mask and PDOP) are exceeded. 

TTFF times at startup are much longer than specified 

At startup (after the first position fix),  the  GNSS  receiver performs an RTC calibration to have an 
accurate internal time source. A calibrated RTC is required to achieve minimal startup time. 

Before shutting down the receiver externally, check the status in MON-HW in field ‘Real Time Clock 
Status’. Do not shut down the receiver if the RTC is not calibrated. 

Содержание EVK-M8T-0-01

Страница 1: ...stract This document describes the structure and use of the EVK M8T evaluation kit and provides information for evaluating and testing u blox M8 positioning technology for timing and raw data applicat...

Страница 2: ...available at www u blox com under Support Product Resources Conformity Declaration u blox or third parties may hold intellectual property rights in the products names logos and designs included in th...

Страница 3: ...3 3 Serial port default configuration 6 4 Device description 7 4 1 Interface connection and measurement 7 4 2 Active antenna 7 4 3 Evaluation unit 7 4 3 1 Antenna connector 7 4 3 2 USB 7 4 3 3 UART 8...

Страница 4: ...ects Evaluation Kit Description Suitable for EVK M8T u blox M8 Timing GNSS Evaluation Kit NEO M8T LEA M8T Table 1 List of products supported by EVK M8T evaluation kit 1 2 Kit includes Evaluation unit...

Страница 5: ...nal limited power source only separated or Safety Extra Low Voltage SELV circuits are to be connected to the evaluation kit including interfaces and antennas For more information about SELV circuits s...

Страница 6: ...Set slide switch to I2C SPI I2C compliant DDC Connect corresponding pins see Table 5 for pin description Set slide switch accordingly to SPI or I2C Press the RST button after changing the switch 2 Th...

Страница 7: ...0 mA 4 3 Evaluation unit Figure 2 shows the front and the rear panel of the EVK M8T evaluation unit Front panel Rear panel Figure 2 EVK M8T evaluation unit front and rear panels 4 3 1 Antenna connecto...

Страница 8: ...n The RST button on the front panel resets the unit To avoid an inadvertent reset the button is recessed 4 3 5 Safe boot button This is used to set the unit in safe boot mode In this mode the receiver...

Страница 9: ...ction for over all current measurement see Figure 5 10 P2A O 3 0 V Battery output unloaded 100 1 resistor for battery backup current measurement to pin 9 P2B NOTE There is a current protection to 3 mA...

Страница 10: ...CR2450 The battery has a rated capacity of 540 mA The battery operating temperature range is 40 C to 85 C If the built in backup battery runs low or is empty after a long storage period purchase the b...

Страница 11: ...download all the Aiding Data via the AssistNow Online service 3 Read the voltage and average if necessary on the voltmeter and convert to current 1 mV equals 1 mA 4 Perform the test with good signals...

Страница 12: ...e save configuration box in u center otherwise the configuration will be lost Communications to the evaluation kit must be via the UART I2C or SPI not USB The evaluation kit can be supplied via the US...

Страница 13: ...EVK M8T User Guide UBX 14041540 R05 Block diagram Page 13 of 22 Early Production Information 7 Block diagram Figure 5 EVK M8T block diagram...

Страница 14: ...ide UBX 14041540 R05 Board layout Page 14 of 22 Early Production Information 8 Board layout Figure 6 shows the EVK M8T board layout PCB Version B See Table 6 for the component list of the EVB Figure 6...

Страница 15: ...M PITCH DISCONNECTABLE CRIMP CONNECTOR 40 85C J6 CON 1 ROW THT 100MIL GRID 2PINS 0 64MM SQUARE 6 1MM HEIGHT L2 IND MURATA LQW15A 0402 120N 5 0 64A 55 125C Q1 MBT3906DW1T1G DUAL GENERAL PURPOSE TRANSIS...

Страница 16: ...EVK M8T User Guide UBX 14041540 R05 Schematic Page 16 of 22 Early Production Information 9 Schematic Figure 7 Schematic EVK M8T DNI TRUE in the schematic means Component not installed...

Страница 17: ...41540 R05 Battery replacement Page 17 of 22 Early Production Information 10 Battery replacement To replace the battery Number 5 in Figure 8 open the unit unscrew four screws on the front panel Figure...

Страница 18: ...le on your computer will show up in the COM port drop down list If a COM Port is gray another application running on this computer is using it The position is off by a few dozen meters u blox M8 GNSS...

Страница 19: ...ngs aren t good This provides safety as it is no longer possible to accidentally program a bad configuration e g disabling the main communication port The EVK M8T does not work properly when connected...

Страница 20: ...have an impact on signal travel time The position of the GNSS receiver is typically not the same between two tests Comparative tests should therefore be conducted in parallel by using one antenna and...

Страница 21: ...ocumentation and to receive product change notifications register on our homepage www u blox com Revision history Revision Date Name Comments R01 07 Nov 2014 amil alnu Advance Information R02 07 Jan 2...

Страница 22: ...p u blox com Regional Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 E mail info_cn u blox co...

Отзывы: