background image

Quick Start -

self-powered iTRV

LED flash pattern

green flash = Successful pairing

3 x flash = Pairing failed

Installation and reference run

Press the push button 1 or 2 ; iTRV adjusts the min 

and max positions. Then enters normal operation.

Pairing-mode

Press the push button 1 or 2 for 5s. You may have to

repeat this step.

Manual Teach-in

Set room controller to pairing mode.

Check the user guide of the room controller.

Additional things to know

 

Connection nut M30 x 1.5 ; adapters are available for 

   many other valve types.

 

Valve should be working freely

 

EnOcean protocol A5-20-01

 

Every 10 min, the iTRV conects to the room

  controller, requesting an update to the valve position  

  or the set temperature. The iTRV then moves the 

  valve to the specified position.

 

Summer mode : Radio communication interval

   increased from 10 min to 8 hours.

 

To remove the valve, press the push button 1 or 2 for 

   5s (mind the key lock) and wait until the motor stops.

   The loosen the coupling nut.

phone : +33 (0)3 59 61 02 41

e-mail : [email protected]

www.ubiwizz.com

1.

Room controller

EnOcean EEP A5-20-01

2.

3.

During the following 10 min the 

iTRV works at a 10s intervals.
Non-installed iTRVs return into 

mounting position.
After one hour, the push

buttons lock automatically.

Unlock by pressing button 1 

and 2 at once for 10s.

DR-MICITR

V004-03

NFC Tag (Quickmove)

Connection nut

M30 x 1.5

QR Code for

Quickmove

Serial number

EnOcean radio ID

Buttons

Ambient tp sensor

Button 1 and 2

LED