![Ubisys 7047 Скачать руководство пользователя страница 26](http://html2.mh-extra.com/html/ubisys/7047/7047_reference-manual_3150151026.webp)
26
www.ubisys.de
Please note that Le is ignored. The stored value is returned without being truncated, independently of
Le.
Response codes
SW1
SW1
Meaning
90
00
Command executed successfully. The configuration item is delivered in the payload.
6B
00
Unsupported parameter P1-P2 combination.
The following configuration items are supported:
Configuration item [P2]
Description
Length
Values
80h
ISO15693 modulation depth
1 byte
00h – 10% modulation depth
01h – 100% modulation depth (OOK)
81h
ISO15693 data-rate
1 byte
00h – low data rate
01h – high data rate
82h
ISO15693 subcarrier setting
1 byte
00h – single subcarrier
01h – double subcarrier
8eh
ISO15693 default memory
configuration
2
2 byte
See table below
8fh
Clear ISO15693 default memory
configuration (write-only)
0
-
The ISO15693 data rates are as following:
Data rate
Single Subcarrier
Dual Subcarrier
Low
6.62 kbits/s
6.67 kbits/s
High
26.48 kbits/s
26.69 kbits/s
Parameter layout for the ISO15693 default memory configuration
Number of blocks (minus 1)
Block size in bytes (minus 1)
1 byte
1 byte
Both values are encoded as the actual value minus 1. This allows encoding values of 1 to 256 for both
fields.
If the default configuration is read back and no default configuration was previously set, an empty
response is returned.
2
This configuration is used if the tag does not support the ISO15693 “Get System Information” command,
which, among other information, returns the memory layout of the tag.